Setup Instructions for 7thSense 3D Sync using Labjack
Additional servers are connected from Pin 3 of their 3 pin Mini-DIN connector to the appropriate
LabJack 15-way D connector pin:
Signal
LabJack
15-way D
Follower Server
3 pin Mini-DIN marking
Follower 1 Sync
Pin 12 (EIO1)
S1
Follower 2 Sync
Pin 5 (EIO2)
S2
Follower 3 Sync
Pin 13 (EIO3)
S3
Follower 4 Sync
Pin 6 (EIO4)
S4
All Gnd signals are connected from the Follower Server 3 pin Mini-DIN plugs pin 2 to the LabJack 15-
way D connector pin 8.
DeltaShowControlInterface
DeltaShowControlInterface
is a small utility that provides a control logic for the Advantech ADAM-
6060 interface module so that Delta shows can be controlled from simple remote switches. A ‘dry’
digital input (switch or pulse) to the ADAM-6060 will send a UDP trigger over Ethernet to the IP of the
required Delta Server to either perform a simple timeline command or trigger a Delta sequence.
, one to operate simple load/loop/stop timeline commands, the
other to trigger prenamed Delta sequences. Any sequence can be written in Delta under a name that
belongs to each input switch.
The Advantech ADAM-6060 illustrated here is a data acquisition and control module with 6 channels
of digital input and 6 channels of relay outputs using Modbus TCP over Ethernet. Please refer to the
specification of this unit for full details and suitability. Use the Advantech .NET utility supplied with
your unit or downloaded from Advantech. Please refer also to the manual supplied with your
Advantech ADAM-6060 unit.
Ø
Advantech ADAM-6000 series User Manual
(2018)
Required Components
·
DeltaShowControlInterface Software v.1.0
·
Advantech ADAM-6060 Interface Unit + Ethernet cable
·
Adam/Apax .NET Utility