background image

Pag 4 | 13   

www.6tlengineering.com

   24/06/2022   YAV90059   

 
 

3. 

DESCRIPTION 

 

The YAV90059 module is controlled through CAN Bus and features104 DPST relays forming 
two 4-poles, 2-Poles or 1-Pole Multi-configuration Multiplexers. 

The configuration of the multiplexer is selected by a software command. The 

‘mode’ is an 

analog output Phi6 function, where the input parameter can be 1 to 13. The modes available are 
the following: 

1.  8 x(1x16) 

 8 banks of 16 individual outputs. This is the default mode. 

2.  4x(1x32) 

 4 banks of 32 individual outputs. 

3.  1x(1x64)  +  2x(1x32) 

  1  bank  of  64  individual  outputs  and  2  banks  of  32  individual 

outputs. 

4.  1x(1x96) + 1x(1x32) 

 1 bank of 96 individual outputs and 1 bank of 32 individual outputs. 

5.  2(1x64) 

 2 banks of 64 individual outputs. 

6.  1(1x128) 

 1 bank of 128 individual outputs. 

7.  8 x(2x8) 

 8 banks of 8 double outputs. 

8.  4 x(2x16) 

 4 banks of 16 double outputs. 

9.  1 x(2x32) + 2x(2x16) 

 1 bank of 32 double outputs and 2 banks of 16 double outputs. 

10. 1 x(2x48) + 1x(2x16) 

 1 bank of 48 double outputs and 1 bank of 16 double outputs. 

11. 2 x(2x32) 

 2 banks of 32 double outputs. 

12. 1 x(2x64) 

 1 bank of 64 double outputs. 

13. 4x(4x8) 

 4 banks of 8 quadruple outputs (2 locked double outputs). 

 

 

 

Summary of Contents for YAV90059

Page 1: ...rdware installation procedures applicable to your application Note the guidelines in this document are specific to the YAV90059 The other components in the system might not meet the same safety ratings Refer to the documentation of each component in the system to determine the safety and EMC ratings for the entire system MORE INFORMATION ON OUR WEBTSITE www 6tlengineering com ...

Page 2: ...LINES 3 3 DESCRIPTION 4 4 LAYOUT AND DIMENSIONS 5 5 RELAY DISTRIBUTION 6 6 PINOUT FRONT 7 7 CONNECTOR PINOUT REAR 8 8 LED BEHAVIOUR 8 9 SWITCH CONFIGURATION 9 10 HARDWARE SPECIFICATIONS 10 11 OPERATION 11 11 1 PHI6 EXPLORER soft interface 11 12 LOW LEVEL CAN COMMANDS 12 13 ACCESSORIES 12 14 UNPACKAGING AND INSTALLING 13 ...

Page 3: ...erating failure of the lift when such failure is due to the parameters incorrect programming The product described in this manual can be configured to comply with the ruling of different countries The manufacturer does not hold any responsibility if the company installing it does not configure it according to the legal commercial or security prescriptions that may be in force in the place of insta...

Page 4: ...x 1x32 4 banks of 32 individual outputs 3 1x 1x64 2x 1x32 1 bank of 64 individual outputs and 2 banks of 32 individual outputs 4 1x 1x96 1x 1x32 1 bank of 96 individual outputs and 1 bank of 32 individual outputs 5 2 1x64 2 banks of 64 individual outputs 6 1 1x128 1 bank of 128 individual outputs 7 8 x 2x8 8 banks of 8 double outputs 8 4 x 2x16 4 banks of 16 double outputs 9 1 x 2x32 2x 2x16 1 ban...

Page 5: ...Pag 5 13 www 6tlengineering com 24 06 2022 YAV90059 4 LAYOUTAND DIMENSIONS All dimensions are in millimetres ...

Page 6: ...Pag 6 13 www 6tlengineering com 24 06 2022 YAV90059 5 RELAY DISTRIBUTION ...

Page 7: ...8 18 18 19 Mux 4 K060 19 Mux 4 K060 19 Mux 4 K059 19 Mux 4 K059 20 Mux 4 K058 20 Mux 4 K058 20 Mux 4 K059 20 Mux 4 K059 21 Mux 4 Comm 21 21 21 Mux 4 Comm 22 Mux 4 K062 22 Mux 4 K062 22 Mux 4 K061 22 Mux 4 K061 23 Mux 4 K064 23 Mux 4 K064 23 Mux 4 K063 23 Mux 4 K063 24 24 24 24 25 Mux 5 K076 25 Mux 5 K076 25 Mux 5 K075 25 Mux 5 K075 26 Mux 5 K074 26 Mux 5 K074 26 Mux 5 K073 26 Mux 5 K073 27 Mux 5 C...

Page 8: ...r and CAN Pin Number Signal Description 1 GND Ground connection 2 24V Board power supply 3 CAN L CAN Bus Low signal 4 CAN H CAN Bus High signal X1 pinout description Plug type Manufacturer Weidmuller Model BLZF 3 50 04 180 8 LED BEHAVIOUR LED Name LED Behaviour Definition of Behaviour STATUS Off Board is not powered on or power supply is not reaching the microcontroller Solid green Board is powere...

Page 9: ...anged The hardware address is selected by switches 3 to 8 being 3 the least significant bit LSB and 8 the most significant bit MSB ON 1 2 3 4 5 6 7 8 ON 1 OFF 0 LSB MSB Board Address SW1 behaviour Switch ID Description Definition of Behaviour SW2 BOOT0 Factory use Must be OPEN on operation SW3 RESET Must be OPEN on operation A temporary bridge causes a reset of the board SW4 CAN END Placing jumper...

Page 10: ... current 24VDC and 25ºC 750 mA CAN Bus operation speed 50 250 kbps Operation specifications Contact data Property Min Typ Max Units Maximum switching voltage 220 250 VDC VAC Rated current 2 A Switching power 60 W Minimum switching voltage 100 mV Operate time 1 3 ms Release time 3 5 ms Bounce time 1 5 ms Initial contact resistance 50 mΩ Relay contact specifications ...

Page 11: ...aintenance on site The panel displays the relays in two pages 4 banks in each page Activate relays By clicking a relay in the panel the relay closes and its status in the panel is updated Reset Reset button will put all relays in Open status Config tags To operate with Phi6 driver each row column must be given a tag name By clicking this button the panel will change its background color from grey ...

Page 12: ...ng com 24 06 2022 YAV90059 12 LOW LEVEL CAN COMMANDS 13 ACCESSORIES Item Description PN ITA Module Quadrapaddle Signal Module 192 Position VP510151105 ITA Quadrapaddle pin Quadrapaddle Signal Contact 7 Amp 20 24 AWG VP610138109 ...

Page 13: ...st remove vacuum bag carefully to avoid damage To install the YAV90059 simply insert the module on a VPC receiver vertical or horizontally according to the Receiver arrangement Once it is completely inserted fix YAV module with two 4 40 UNC screws on each side of connector Tight them using a 3 32 Allen wrench at full revolutions Torque should be 0 45Nm max Finally connect the X1 rear plug of CAN b...