background image

  

50mm

2"

  

  

51mm

2"

  

Corner Wall 

  

102mm

4"

  

  

102mm

4"

  

  

152mm

6"

  

HORIZONTAL INSTALL-EXHAUST

Rear Wall or Alcove

  

152mm

6"

  

406mm

16"

U.S.A.

  

203mm

8"

  

  

203mm

8"

  

458 mm

18"

 

CANADA

Floor Protection

  

102mm

4"

  

  

102mm

4"

  

  

229mm

9"

  

VERTICAL INSTALL-EXHAUST

Rear Wall or Alcove

  

975mm

39"

  

Minimum Ceiling Height 

Clearance is 40" / 1016mm.

HORIZONTAL INSTALL-EXHAUST

Rear Wall or Alcove

How to Install the stove

The stove should be installed by a licensed stove company or a licensed HVAC Technician.  Some states and counties require permits be obtained before you install 
your stove.  
The outlet on the bottom combustion blower motor is 3” in diameter.  Double wall pipe with stainless steel for the inner liner must be used in all installs.  It is most 
commonly called Pellet Pipe. Three inch (3 inches) (76mm) diameter Listed DOUBLE WALL pipe with MH8381
& MH14420) to UL 641 Type L Low Temperature Venting Systems** Listed factory-built Class "A" chimney, or
a masonry chimney.(**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650oC Factory-built chimney.)

FLOOR PROTECTION:

Floor protector must be 1/2 in. minimum noncombustible material extending beneath heater and to front/sides/rear as indicated on the diagram below.
Exception: Non-combustible floor protections must extend beneath the flue pipe when installed with horizontal venting and extend 2 inches (51mm)
beyond each side.
The stove is designed to be pushed back to within inches of the back wall and to be at least one foot from any sidewalls or any other surface. Check with your local 
permit inspector to verify your clearance from combustibles in your state.  We have UL specifications on the stove for clearance to combustibles. Add here after 
striking 8. Refer to this manual and the drawings for install specifications.

 When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote.  The creosote 
vapors condense in the relatively cool chimney flue of a slow-burning fire.  As a result, creosote residue accumulates on the flue lining.  When 
ignited this creosote makes an extremely hot fire.
The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote 
buildup has occurred.  If creosote has accumulated, it should be removed to reduce the risk of a chimney fire.
Using "Make-Shift" parts or not following the guidelines of correct installation procedures and clearances can result in failure of the stove or a fire 
in your home.
 The chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling.  Where passage 
through a wall or partition of combustible construction is desired, the installation shall conform to Can/CSA-B365, Installation Code for Solid-Fuel-
Burning Appliances and Equipment.
Clearances may only be reduced by means approved by the regulatory authority. 

DO NOT INSTALL IN A MOBILE HOME.

IT IS RECOMMENDED IN CASE OF POWER OUTAGE TO HAVE AT LEAST 2 FT OF RISE ABOVE MOTOR ELEVATION 
IN STOVE PIPE BEFORE TERMINATING EXHAUST.

DuraVent - PelletVent Pro - Pipe 

Building structure and Air intake and output, The following pages show  requirments per UL testing of this stove
509 FAB suggest's the DuraVent products and Specifactions ( 

See Attached Manual

 ) As an Industerial leader in Pellet Stove Pipe products

Summary of Contents for 509-1 OPTIMUM

Page 1: ... FOR SOLID FUEL TYPE ROOM HEATERS UL 1482 2011 R2015 ULC S627 00 SPACE HEATERS FOR USE WITH SOLID FUELS Edition 3 Issue Date 2000 06 01 OMNI PROJECT NUMBER 0559WS001E 0559WS001S MANUAL REVISION DATE 01 12 2019 OPTIMUM ...

Page 2: ...MODEL 509 1 OPTIMUM ...

Page 3: ...standards using densified fuel logs This wood heater was found to have an average emissions rate of 1 5 g hr using ASTM E2779 This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual Glass and other surfaces ...

Page 4: ...ld include running at the low to mid range setting with occasional running on the maximum setting during the coldest periods of the winter The blower speed control should be turned to HIGH when operating the stove on the high heat setting CAUTION HOT IN OPERATION An appliance hot enough to warm your home can severely burn anyone touching it Keep children clothing 12 and furniture away Contact may ...

Page 5: ...designed to be air tight Let the fire go out naturally Do not have the lid and the door open at the same time while the fire is burning You will get smoke in the room Only open one at a time Do not burn wood or any other substance in this stove except natural densified fuel logs with no additives Burning these types of fuel will void your warranty and heavily damage the inner workings of the stove...

Page 6: ...bles in your state We have UL specifications on the stove for clearance to combustibles Add here after striking 8 Refer to this manual and the drawings for install specifications When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result...

Page 7: ... The materials in these logs will also clog up the way the stove breathes to be able to operate efficiently and it will also plug up the fan blades on the motor that takes the exhaust out of the stove Most of these logs that are not designed to be burned in your stove will have a wrapper on the log Some examples of these types of logs are DO NOT BURN A Duraflame B Java Log C Pine Mountain D Enviro...

Page 8: ...e round switch that is located towards the front of the stove to the full on position It will stop when it is fully on 11 Turn on the Combustion blower motor the second middle switch to the up position 12 Turn the igniter Dial Switch so it goes past 5 and then turn back to 3 This will power the igniter to start the fire 13 When you see flames inside the stove pull the damper to Medium or High 14 M...

Page 9: ...r and open the feed tube lid Using a suitable tool like a round rod tap the log from the lid side down the feed tube It will fall into the firebox Open up the damper by sliding it towards the rear of the stove and let it burn on high for hour and then reset to your desired setting My stove is not putting out any heat Check the combustion blower and make sure it is on It is powered ON by the middle...

Page 10: ... the edge of the door and lightly tap on the bottom of the door to lift it off the 3 hinges being careful to not let the little brass washers on the hinge not come off with the door removal If the brass washers come off they must be put back down on the post of the hinge before the door goes back on Put the door on a flat surface with the outside of the door down Take the new glass and with gloves...

Page 11: ...LASS REPAIR REPLACEMENT CAUTION Follow instructions completely and always wear leather gloves when removing the glass or removing broken glass CAUTION NEVER OPERATE THE STOVE WITH BROKEN GLASS CAUTION NEVER USE ABRASIVE CLEANERS CAUTION DO NOT CLEAN GLASS WHEN HOT WARNING Never Use Substitute Materials WARNING Never slam the door shut strike the glass or abuse the glass in any way ...

Page 12: ...tem 170 See Picture DOOR and FEED TUBE LID GASKETS Gaskets for both of these applications are available on our website or from a dealer in your area The gasket is called 3 4 Double Core Fire Rope Hytex 1000 Part RK0092 These gaskets need to be installed after thoroughly removing the existing gasket and cleaning the adhesive residue completely out of the channel An adhesive called High Temp Stove G...

Page 13: ...um only to do this It is what they are made for and then the dust will not blow in the house The ash vacuums are available on my website Inspect the firebox by sliding the front brick to the side or removing the brick Use a flash light to look in the firebox If needed vacuum the 3 firebox out completely VERY IMPORTANT Every day take the special wrench provided and using the pin end slide it into t...

Page 14: ... rod and wrench handle every day This is a 30 second procedure One time a year the Lower Combustion motor should be removed and cleaned The blades will have buildup on them from regular burning This buildup needs to be removed and cleaned by a professional and the motor re installed making sure all nut fasteners and lock washers are used for re install and tightened down securely Do not over tight...

Page 15: ...gh Temp RTV sealant and 3 self drilling tapping screws Attaching the 509 1 Optimum Elbow will transition your exhaust to the horizontal position The exhaust elbow can be attached to a 3 to 4 or 3 to 3 Exhaust cleanout T Exhaust Pipe for your vertical exhaust termination or to an appliance adapter and pellet pipe to go out the wall horizontally It is recommended to put a minimum of 3ft rise above t...

Page 16: ...ront facing brick It has been cut down for air flow The bricks can be obtained on the website or a home improvement store The inside row of bricks are identified and counted from the front facing brick that stands on its side Front brick is 1 brick 2 is to the left brick 3 is in the back and brick 4 is the one on the right These bricks are all special to their designated placement and how they are...

Page 17: ...FIMB 5091 912 BLOWER 5091 900 C515M 001 16g GREEN BSV18X LY 18g BROWN 16g BLACK 16g WHITE 16g BLACK 16g BLACK 16g WHITE 16g WHITE 16g BLACK PV14 8RB 3K GROUND OUTLET GROUND ELEC BOX POWER AT WALL 16g BLACK 18g BLUE 16g BLACK OUTLET 4 40 SCREW STANDARD 6 FOOT CORD OUTLET HARNESS 3 PRONG HARNESS FAN HARNESS IGNITER HARNESS BLOWER HARNESS IGNITER DNF14 250FIB DNF14 250FIB 16g BLACK DNF18 250FIB DNF18...

Page 18: ...warranted for 1 year from date of purchase 3 The Combustion blower motor is warranted for 1 year from date of purchase 4 The glass is warranted for 1 year from date of purchase 5 The fire bricks do not have any warranty 6 The stove paint is warranted for a period of 1 year by original owner Scratches and nicks are not warranted only complete paint failure 7 One year warranty on igniter 509 Fabrica...

Reviews: