Product Options | 19
Aprisa SR+ Product Description
Switch Over
The switch over to the standby radio can be initiated automatically, on fault detection, or manually via
the Hardware Manual Lock switch on the Protection Switch or the Software Manual Lock from SuperVisor.
Additionally, it is possible to switch over the radios remotely without visiting the station site, via the
remote control connector on the front of the Protection Switch.
Configuration Management
The Primary and Secondary radios are managed with the embedded web-based management tool,
SuperVisor, by using either the Primary or Secondary IP address. Configuration changes in one of the radios
will automatically be reflected in the partner radio.
To ensure all remote stations are registered to the correct (active) base station, changes to the Network
Table are automatically synchronized from the active radio to the standby radio. The Network Table is
only visible on the active radio. This synchronization does not occur if the Hardware Manual Lock is active.
Summary of Contents for Aprisa SR+
Page 1: ...April 2013 Version 1 0 0 03 for General Availability Release in October 2013...
Page 2: ......
Page 6: ......
Page 9: ...Contents vii 7 Contact Us 47...
Page 10: ......
Page 32: ......
Page 48: ...46 Architecture Aprisa SR Product Description Aprisa SR Block Diagram...