background image

17

GB

Before starting device up for the first time / Operation

q

  

Before starting device up 

for the first time

J   

Clean the battery clips. Make sure that your 

eyes do not come into contact with rust.

J   

Ensure sufficient ventilation. Gaseous hydrogen 

can leak out when charging or trickle charging 

the battery.

q

  

Operation

q

  

Connection

j   

Connect the connecting cable 

p

 or 

[

 to the 

connection adaptor 

]

.

j   

Clamp the “+”-pole (red) 

y

i

 of the charger 

to the “+”-pole of the battery.

j   

Clamp the “–”-pole (black) 

u

o

 of the 

charger to the “–”-pole of the battery.

 

 

Note:

 Make sure that the “+”-pole 

y

i

 or 

the “–”-pole 

u

o

 sits firmly. 

j   

Connect the power cable 

r

 to the mains current.

As soon as you have connected the battery to the 

charger, the charger automatically switches to 

STANDBY mode. The “POWER” display 

w

 glows.

Note: 

The charger has its own reverse battery 

protection. The LED 

 “Error” 

Q

 shines when the 

“+”-pole 

y

i

 or “–”- pole 

u

o

 has been wrongly 

connected.

q

  

Disconnecting

j   

Disconnect the power cable 

r

 from the mains 

current.

j   

Remove the “–”-pole (black) 

u

o

 of the 

charger from the “–”-pole of the battery.

j   

Remove the “+”-pole (red) 

y

i

 of the charger 

from the “+”-pole of the battery.

q

  

Select mode of operation

j   

Press the “MODE” button 

q

 to select the mode 

of operation you want to have. The LED for the 

mode of operation you want will glow steadily.

You can choose between the following modes 

of operation:

Mode 1   28.8 V (24 V / 3.5 A):

Suitable for batteries with a capacity of more than 

14 Ah in normal conditions. Charging mode for 

open batteries, MF and for most GEL batteries.

-   The LED for Mode 1 

}

 lights up. As soon as 

the integrated switch is thrown, the appropriate 

LED for the state-of-charge also comes on 

(see “State of charge”). The charging process 

starts with an amperage of 3.5 A. As soon as 

the battery has been fully charged (28.8 V) the 

following LEDs light up:   

W

,   

E

,   

R

 

and   

T

.

 

 The charger changes over to trickle charging.  

If the voltage of the battery falls below 25.6 V, 

the charging process starts up again with an 

amperage of 1.5 A until the battery has been  

fully charged again (28.8 V).

Mode 2 

 29.4 V (24 V / 3.5 A):

Suitable for batteries with a capacity of more than 

14 Ah in cold conditions or also for many AGM  

batteries (with electrolyte-absorbing mats) with a 

capacity of more than 14 Ah.

-   The LED for Mode 2 

{

 lights up. As soon as the 

integrated switch is thrown, the appropriate LED 

for the state-of-charge also comes on (see “State 

of charge”). The charging process starts with an 

amperage of 3.5 A. As soon as the battery has 

been fully charged (29.4 V) the following LEDs 

light up:   

W

,   

E

,   

R

 and   

T

.

 

 The charger changes over to trickle charging.  

If the voltage of the battery falls below 25.6 V, 

the charging process starts up again with an 

amperage of 1.5 A until the battery has been 

fully charged again (28.8 V).

Mode 3   14.4 V (12 V / 7 A):

Suitable for batteries with a capacity of more than 

14 Ah in normal conditions. Charging mode for open 

batteries, MF and for most GEL batteries.

-   The LED for Mode 3 

P

 lights up. As soon as the 

integrated switch is thrown, the appropriate LED 

battery_charger_7.0_Content_EU.indd   17

09.12.08   16:59

Summary of Contents for Charge Box 7.0

Page 1: ...WWW 4LOAD DE CHARGE BOX 7 0 BATTERY CHARGER 7 0 AMP WWW 4LOAD DE USER MANUAL ...

Page 2: ...11 6 10 1 2 13 19 18 21 20 16 17 15 8 7 3 4 5 14 9 12 24 23 22 ...

Page 3: ...evice up for the first time Page 17 Operation Connection Page 17 Disconnecting Page 17 Select mode of operation Page 17 State of charge Page 18 Trickle charging 13 6V SUPPLY Page 18 Regeneration mode 16V BOOST Page 19 Impulse charging Page 19 Charger protection function Page 19 Overheating protection Page 19 Memory function Page 19 Average charging time Page 19 Maintenance Page 19 Disposal Page 20...

Page 4: ...del 1 Directions for use q Description of parts Q Error W Charging 25 E Charging 50 R Charging 75 T Trickle charging 100 Y SUPPLY LED Electrical power supply U Regeneration mode 16V BOOST I Maintenance mode 13 6V SUPPLY O Mode 4 14 7V P Mode 3 14 4V Mode 2 29 4V Mode 1 28 8V q MODE button w POWER display ON OFF e Charger The following pictogrammes symbols are used in these operating instructions R...

Page 5: ...ower cord causes danger to life by electric shock J If damaged have the power cord repaired by authorised and trained technicians only J Do not allow toddlers or children near the charging station without super vision Children cannot assess the potential danger in the handling of electrical equipment J Children or persons who lack the knowledge or experience to use the device or whose physical sen...

Page 6: ...e vehicle first disconnect the cable of the negative minus pole black of the charger from the negative minus pole of the battery J Always turn your face away from the battery when you connect the charging cable to the battery J In case of malfunction or damage immediately disconnect the charging station from the mains J Have the charging station repaired by authorised and trained specialists only ...

Page 7: ...ries with a capacity of more than 14Ah in normal conditions Charging mode for open batteries MF and for most GEL batteries The LED for Mode 1 lights up As soon as the integrated switch is thrown the appropriate LED for the state of charge also comes on see State of charge The charging process starts with an amperage of 3 5A As soon as the battery has been fully charged 28 8V the following LEDs lig...

Page 8: ... fully charged again 14 4V q Trickle charging 13 6V SUPPLY Note In this mode the charger has overload protection max 6 0A Note As soon as the output voltage falls below 4 5V the charger automatically switches to STANDBY mode Caution There is no reverse battery protection in this mode see Connecting Suitable for maintaining the state of charge of batteries with a capacity of more than 14Ah in norma...

Page 9: ...ected before This process is able to regenerate most flat used or overcharged batteries so that they can be re used q Charger protection function As soon as an abnormal situation such as a short circuit regeneration process of more than 7 hours charging process of more than 41 hours battery voltage less than 4 5V with 12 V batteries or 16V with 24 V batteries open electric circuit or reversed pola...

Page 10: ...ycling centre Do not dispose of electrical appliances in household waste q Information q Servicing J Have your device repaired only by quali fied specialist personnel using original manufacturer parts only This will ensure that your device remains safe to use We reserve the right to make technical modifications in the course of product development ...

Page 11: ...4 Load GmbH Glendale Str 4 87700 Memmingen Germany www 4load de ...

Reviews: