5. Operation
Page 5
00
:
00
100
050
d. Press the button “Start/Stop” to start automatic curing mode. Once the automatic
mode is selected, Four related cure programs become available to the user – Program
1-4(Fig. A).
e. Protect the lamp against shocks and vibrations when the lamp is in use.
g. After this program is completed, the system is able to carry out other programs. Make
sure to turn off the system when the equipment is not in use and keep the equipment
securely in place.
Program 1
Program 2
Pulse Time (3min)
Power
(
70
%)
Routine
Time
(
5
min
)
Power
(
65
%)
Pulse Time (3min)
Power
(
60
%)
Routine
Time
(
5
min
)
Power
(
55
%)
step1
step2
step3
step4
Fig. A
The time and power of each step can be adjusted
during execution, but it won't change the default data.
If you want to change the default data of automatic
mode, adjust the parameters as follows before pressing
"Start":
1). Once switching on the power supply, the display
automatically defaults to Step 1 of the automatic mode.
2). Press "Routine" once, switches to Step 2; press
again, switches to Step 3; keep pressing, switches
recurrently.
3). When switch to each step, adjust the time and
power by Button 2 and 4, stay unchanged for 3 seconds
then the data will be automatically saved as default
setting for this step.
4) To initialize all data, press and hold the distance
adjustment b and - at the same time.
c.
Move forward or backward heat lamp to adjust to the best distance.
Distance data will be detected and displayed on the screen.
Roast lamp lamp holder and paint surface distance according to the paint
material and weather conditions to adjust the humidity of the (air humidity).
Under normal circumstances,Advised to keep distance from 35 to 45 cm.
Time to adjust
Distance adjustment
Power adjustment
1.Automatic Mode
a. Properly assemble the curing system according to the instruction (see page 3).
b. Switch on the power supply. The display will go through the start-up procedure and
automatically default to Automatic Mode. The system is ready to use when the
parameters appears on the display screen as follows: