3.  SELECT A QUALIFIED AND COMPETENT INSTALLER

Correct installation of the product is important for safety and performance.  If you have 

not asked 4B to perform the installation of the unit on your behalf, it is critical for the 

safety of your operation and those who may perform work on your operation that you 

select a qualified and competent electrical installer to undertake the installation.  The 

product must be installed properly to perform its designed functions.  The installer should 

be qualified, trained, and competent to perform the installation in accordance with Local 

and National Electrical Codes, all relevant OSHA Regulations, as well as any of your 

own standards and preventive maintenance requirements, and other product installation 

information supplied with the product.  You should be prepared to provide the installer 

with all necessary installation information to assist in the installation.

4.  ESTABLISH AND FOLLOW A REGULAR MAINTENANCE AND INSPECTION 

SCHEDULE FOR YOUR 4B PRODUCTS

You should develop a proper maintenance and inspection program to confirm that your 

system is in good working order at all times.  You will be in the best position to determine 

the appropriate frequency for inspection.  Many different factors known to the user will 

assist you in deciding the frequency of inspection.  These factors may include but are not 

limited to weather conditions; construction work at the facility; hours of operation; animal 

or insect infestation; and the real-world experience of knowing how your employees 

perform their jobs.  The personnel or person you select to install, operate, maintain, 

inspect or perform any work whatsoever, should be trained and qualified to perform these 

important functions.  Complete and accurate records of the maintenance and inspection 

process should be created and retained by you at all times.

5.  RETAIN AND REFER TO THE OPERATION MANUAL FOR 4B’S SUGGESTED 

MAINTENANCE AND INSPECTION RECOMMENDATIONS

As all operations are different, please understand that your specific operation may require 

additional adjustments in the maintenance and inspection process essential to permit 

the monitoring device to perform its intended function.  Retain the Operation Manual 

and other important maintenance and service documents provided by 4B and have 

them readily available for people servicing your 4B equipment.  Should you have any 

questions, please call the free 24-hour hotline number (309-698-5611).

6.  SERVICE REQUEST

If you have questions or comments about the operation of your unit or require the unit to 

be serviced please contact the 4B location who supplied the product or send your request 

via fax (309-698-5615) or call us via our 24-hour hotline number in the USA (309-698-

5611).  Please have available product part numbers, serial numbers, and approximate 

date of installation.  In order to assist you, after the product has been placed into service, 

complete the online product registration section which is accessed via our website www.

go4b.com/usa.

Summary of Contents for ADBT2

Page 1: ...www go4b com usa ADB Sensor Tester ADJUSTABLE DEPTH BEARING SENSOR TEMPERATURE TESTER OPERATION MANUAL Part No ADBT2 Batteries Not Included...

Page 2: ......

Page 3: ...RESPONSIBILITIES Page 4 5 PRODUCT OVERVIEW Page 6 SPECIFICATIONS Page 7 DIMENSIONS Page 7 BATTERY INSTALLATION Page 8 TESTER OPERATION Page 9 TROUBLESHOOTING GUIDE Page 12 PRODUCT WARRANTY Page 15 TA...

Page 4: ...asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to your industry Please see the article Haz...

Page 5: ...tion work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install o...

Page 6: ...re monitoring system Using indirect mode allows simulated testing of NTC type sensors within the network of 4B s T500 Hotbus control unit By connecting the ADBT to a TN4 node testing of the node and t...

Page 7: ...ecommended Temperature Control Range Direct Testing Mode 140 F to 190 F 60 C to 90 C Indirect Testing Mode 77 F to 220 F 25 C to 105 C Temperature Set Control Adjustable by 10 F or 5 C Increments Disp...

Page 8: ...lly unplug the ribbon cable Image C and then insert the two 9 volt batteries Image B Be sure to match the and indications on the batteries with the and indications on the battery compartment To reasse...

Page 9: ...elect F Image D If no button is pressed within two seconds after powering up the ADBT will default to the previously selected temperature setting Direct mode uses the integrated heating block within t...

Page 10: ...open circuit with the front of the ADBT facing toward you turn the knob all the way counter clockwise until it clicks Image I For temperature range testing start in the open circuit position and then...

Page 11: ...PAGE 11 IMAGE H Indirect Testing Mode Output Cable Plugged Into TN4 Node IMAGE I Indirect Testing Mode Temperature Simulation Control Knob CLOCKWISE...

Page 12: ...ctioning replace 9 volt batteries Battery Low Light Indicator Heater Block not Warming Replace AA batteries ADB Sensor not Responding as Expected to Testing 1 Make sure the ADB sensor probe is securel...

Page 13: ...PAGE 13 NOTES...

Page 14: ...NOTES PAGE 14...

Page 15: ...UCT MISUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE AL...

Page 16: ...ica Tel 27 0 11 708 6114 Fax 27 0 11 708 1654 4B AUSTRALIA Unit 1 18 Overlord Place Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3711 2565 Fax 61 0 7 3711 2574 4B COMPONENTS LTD 625 Erie Avenue M...

Reviews: