6.5) Check the LEDs on the front panel of Elios4you and make sure they report the correct feed-back
from the device
6.3) Repeat the procedure for the Live-phase from the Mains electrical meter
WARNING:
place the CT making sure that the green point is directed towards the Residual-Current Circuit Breaker
WARNING:
make sure that all the household electrical appliances are connected to the electrical system in between
the 2 CTs and the related meters. Otherwise, the resulting measurements will not be reliable.
WARNING:
any change to the CT cable length would lead to an increased error rate in data collection. 4-noks does
not recommed such alteration of the device.
6.4) Power Elios4you measuring device as shown on the wiring scheme, paying attention to the
phases sequence
b) Grab the GENERATION CT
c) Securely clamp the CT over the Live-
phase cable
from RCCB
to the meter
6.2) Carry out the connections
a) Identify the Live-phase that comes from
the GENERATION meter
Mains
Generation
Household
N
N
L
L
N
L
Generation - WHITE
Exchange - YELLOW
Pag 13
Elios4you Installation - (Power Reducer E4U ONLY)
6
6.1) Mount Elios4you on DIN rail within the consumer unit
1
A
Before mounting Elios4you, remove the sticker / label stating USER
and PASSWORD. Store it in a safe place to access the dashboard.
WARNING:
the device must be installed inside an electrical panel. Use the appro-
priate caution to let the the Radio Transmitter inaccessible to the end
user, ensuring at the same time the possibility of operation by skilled
personnel during technical assistance.
- if it is not possible to fit Elios4you inside the general switchboard, you will need to use an additional panel enclo
-
sure -
WARNING:
E4U