background image

INSTALLATION

1.  Secure the device on a DIN rail, following the connections showed in the previous scheme (Fig.1 

and Fig. 2).

2.  Once the device is installed and powered on, download the free Elios4you APP on your own 

smart device (smartphone or tablet) from 

Playstore

 (Android) or 

App Store

 (iOS)

3.  Open the App and start the Wizard Configuration, following the steps visible on your smartphone/

tablet (read the Elios4you APP Quick Guide for further information)

4.  Set correct parameters for your PV system and your energy provider using the App menu:

 

- Press 

 “Menu” button

 

- Select 

 “Parameter Settings”

 

- Select “Energy Management” and set values

 

- Press OK when finished to save new values.

5.  Ensure the data values are correct:

 

- Press 

 “Home” button to to go the “Energy Performance” page

 

- Check that energy “Generation” value 

 has a similar value to that from the inverter

 

- Check that the energy “Consumption” 

 value relative to the real-time consumption you 

have in the property.

ATTENTION:

 Configuring Elios4you in “Indirect Mode” grants access through the broadband Router/

AP, allowing all data to be sent to the 4-Cloud, visible remotely through the Elios4you APP (when 
4-Cloud is activated) and also via the 4-Cloud Dashboard (web-portal). Go to http://www.4-cloud.
org and follow the instructions to register your device. Using the credentials on the label provided 
(see left).

Problem

Solutions

1. I can’t see my PV system en-

ergy generation in the App’s 
Home Page

a. Change the Generation CT clamp (white label) orientation, by inverting the green dot (or the arrow direction inside the clamp) 

to the opposite direction.

b. Check that the Generation CT clamp (white label) is only clamped around the PV Live cable (not including the Neutral cable).
c. Check that the CT clamp core is not broken or cracked inside (you may hear a buzzing noise).
d. Check that the Generation CT clamp (white label) is properly closed - be sure not to apply excessive force.

2. The energy generation visible 

on the App is definitely less 
than the value read from the 
inverter

a. Ensure that the Elios4you transmitter is powered from the same Live phase as the Mains CT clamp (yellow label).
b. Check that the Generation CT clamp (white label) is properly closed - be sure not to apply excessive force.

3. The Consumption line has 

the same shape as the Gen-
eration line in the graph

a. Ensure that the Mains CT clamp (yellow label) is clamped over the Mains Live phase cable after the Mains Meter and before 

the Consumer Unit and/or any Henley Block. Failing to do so will not give an accurate measure of total consumption.

b. Ensure that the Neutral cable is not included within the Generation / Mains CT clamps.
c. Check that the CT clamp cores are not broken or cracked inside (you may hear a buzzing noise).

4. It seems that the Consump-

tion values are only being 
shown in the “Grid” icon

a. Ensure that the Mains CT clamp (yellow label) is clamped over the Mains Live phase cable after the Mains Meter and before 

the Consumer Unit and/or any Henley Block. Failing to do so will not give an accurate measure of total consumption.

5. I can never see “Purchased 

Energy” in my system

a. Ensure that the Mains CT clamp (yellow label) is clamped over the Mains Live phase cable after the Mains Meter and before 

the Consumer Unit and/or any Henley Block. Failing to do so will not give an accurate measure of total consumption.

6. During the night the con-

sumption is zero, while dur-
ing the day consumption is 
always more than the ex-
pected value

a. Change the Mains CT clamp (yellow label) orientation, by inverting the green dot (or the arrow direction inside the clamp) 

to the opposite direction.

7. The App shows a consump-

tion value much higher than I 
would expect.

a. Change the Mains CT clamp (yellow label) orientation, by inverting the green dot (or the arrow direction inside the clamp) 

to the opposite direction.

b. Ensure that the Mains CT clamp (yellow label) is clamped over the Mains Live phase cable after the Mains Meter and before 

the Consumer Unit and/or any Henley Block. Failing to do so will not give an accurate measure of total consumption.

TROUBLESHOOT

General Characteristics

n°8 led of functionality diagnostic; Parameter configuration with Tablet

Radio Characteristics

Wi-Fi 802.11b; Access point (AP) Station (STA),B; Output Power 15 +- 1 dBm
Red Cap (only Elios4you Smart); ZIGBEE Home Automation Profile (HA1.2)
2405 MHz ÷ 2480 MHz; IEEE 802.15.4 compatible; Nominal transmission Power +10dBm; Internal PCB Antenna

Power Supply

- 20% 2 W

Internal Memory

Historical data up to two months with sampling every 15 minutes

Alarms

External alarm: free contact connected to the inverter or auxiliary contact breakers; Lack of production in absence of 
data after 4 hours in the central time zone (from 10.00 to 14.00)

Connections

Screw terminals for 230 V ac; Screw terminals for CT; Screw terminals for signal input alarm

Antenna

Wi-Fi external antenna SMA RP connector.

Environment Parameters

Operting temperature 0 + 50°C; International Protection IP45

CE Declarations of 
Conformity

Compliant with directives 2004/108 CE  (Directive EMC) 2006/95 CE (Low Voltage Directive)/ 99/5 CEE (Radio 
Equipment Directive). Standards and/or technical specifications applied: ETSI EN 300 328v1.8.1:2012-06; ETSI EN 
301 489- 17v2.2.1:2012; ETSI EN 301 489-1v1.9.2:2011; EN 61326-1:2013; EN 60950-1:2006 + A11 (2009)

Dimensions (mm)

LED

Button

76

LED

Button

SMART PLUG

SMART SWITCH

1.  Open the Elios4You APP
2.  Press Menu Button 

 --> Red Cap --> Activate Red Cap --> Confirm

SMART PLUG / SWITCH PAIRING

ATTENTION:

 When pairing devices for the first time, keep devices within close range to the Elios4you 

transmitter. The devices can then be moved around to required position after pairing is complete. 
The Smart Plug/Switch does not need to be close to the Wi-Fi router, as the Smart Plug/Switch 
communicates using ZigBee RF (directly to the Elios4you transmitter) and not through Wi-Fi.

1.  Verify that your smart device (smartphone/tablet) is within radio range of the Wi-Fi and/or 

Elios4you.

2.  Install the Plug/Switch to be paired to Elios4you.
3.  Make sure that the Plug/Switch is not paired with a network already (Red LED flashing), otherwise 

perform the disassociation before continuing (see manual for Smart Plug/Switch).

4.  Select Menu icon in the Elios4you App 

 App --> Red Cap -->  Add Smart Plug.

5.  Carefully follow the Wizard in the Elios4you App.

6.  Once complete, go back to the Home Screen of the App 

 select the Consumption icon: 

 

taking you to the Consumption Details page where you will see icons for the management of 
individual appliances .

7.  To modify the settings of individual Plug/Switch, select the corresponding icon 

NOTE: 

repeat the above procedure for the installation of additional Smart Plug/Switch.

ATTENTION:

 Within 1 minute of the pairing procedure, you will be able to see the Smart Plug/Switch 

state in the Elios4you App.

DIFFERENT STATES OF THE SMART PLUG/SWITCH IN THE APP:

GREY

Shows the OFF state (off) 

for both the manual mode 

and/or automatic mode.

YELLOW

Shows the ON state (on) 

for both the manual mode 

and/or automatic mode.

RED

Shows the OFFLINE state, 
meaning the plug/switch is 

off from the mains, or is out 

of radio range.

Elios4you Front Panel Icons

MANAGING APPLIANCES VIA 
ELIOS4YOU

SMART

 OR RED-CAP ACCESSORY

TECHNICAL SPECS

Blink frequency 
proportional to the 
amount of generated 
energy of the pv plant

(red)

Blink frequency 
proportional to the 
amount of energy 
exchanged with the grid

(red)

If ON: energy currently 
being purchased from 
the grid

(red)

If ON: energy currently 
being sold to the grid

(green)

Power supply

(green)

Wi-Fi on

(green)

General alarm or 
failed attempt to 
get connected to 
the smart device

(red)

Not used

(green)

ATTENTION

ATTENTION

ATTENTION

DO NOT CONNECT THE SMART PLUG/
SWITCH TO:

- medical equipment: the involountary deactiva-
tion can cause life-threatening situations
- devices that can cause damage, injury or fire in
case of accidental activation (eg. irons)
- appliances that can be damaged by turning on 
/ off frequently
- appliances that cannot be interrupted
- appliances that require a continuous current 
supply.

ATTENTION:

 Always seek advice from the 

manufacturer or user manual of the appliance 
if it is suitable to control via radio plug or timer.

ATTENTION: 

Be sure to configure the Smart 

Plug/Switch correctly, as per the instructions 
from specific appliance manufacturers.

WARNING:

 if the generation energy LED 

 

does not blink when the PV installation is 
producing energy, it is necessary to invert the 
Generation CT orientation by swapping the 
connection of the wires of Elios4You (terminals 
7 and 9).

WARNING:

 if the LEDS 

 

 detect the 

wrong energy flow (“sold” energy when it should 
report a situation of “purchased” energy or vice 
versa), it is necessary to invert the mains CT 
(yellow label) by swapping the connection of the 
wires of Elios4You (terminals 10 and 12).

WARNING:

 Ensure that the positioning of the 

Generation & Mains CTs are correct to the 
wiring of the property. Otherwise the resulting 
measurements may not be reliable. Ensure the 
Mains CT clamp is positioned after the Mains 
Meter, but before the Consumer Unit. Taking into 
account any Henley Blocks / Split Junctions.

WARNING:

 Alterations to the length of CT 

cables may cause increases in marginal errors 
during measurements. We do not recommend 
such alterations of the device.

ATTENTION:

 

Before installing Elios4you, remove 

the label with device credentials and attach below 
(or keep in a safe place) for future reference and/or 
monitoring via the 4-Cloud Dashboard (web-portal) 
www.4-cloud.org

ID CODE: 00000

Register on:

www.4-cloud.org

and associate your device

with USER: 

XXXXXXXX

ATTENTION:

 If you are configuring the Elios4you 

APP via the Router/AP, data will be visible via 
the 4-Cloud Dashboard after approximately 1 
hour from configuration.

Reviews: