![3Ware 720-0087-00 Manual Download Page 19](http://html1.mh-extra.com/html/3ware/720-0087-00/720-0087-00_manual_3215340019.webp)
Command Line Interface
www.3ware.com
16
maint add spare
Description:
To add a spare drive to port 3 on controller 0.
Example:
Escalade CLI> maint add c0 p3 spare
Sample of output:
Successfully added a SPARE to port 3 on con-
troller 0
maint remove
Description:
To remove a disk drive from port 3 of controller 0.
Example:
Escalade CLI> maint remove c0 p3
Sample of output:
Successfully removed drive from port 3 on
controller 0
maint rebuild
successful
Description:
To rebuild a degraded array, unit 2 (u2) on controller 0, with a disk drive
that is attached to port 3.
Example:
Escalade CLI> maint rebuild c0 u2 p3
Sample of output:
Rebuild started on unit 2 on controller 0
maint rebuild
failed
Description:
To rebuild a degraded array unit 2 (u2) on controller 0, with a disk drive
that is attched to port 3.