Reset to factory setting:

Reset to 

factory setting

OK

Restoring the factory setting will delete all settings and transmitters!

The solar panel then automatically goes into sleep mode. No programming can be carried out in the sleep mode.  
To end the sleep mode, press and hold the program key for 2 seconds > the tube motor starts up once and the solar panel switches to pairing mode.

2

  Delete all paired transmitters

All transmitters 

are deleted

OK

1 x Press button 

P2 / Set Up

1 x Press 

Stop-button

1 x Press button 

P2 / Set Up

Tubular motor starts 1 x,

LED indicator flashes 1 x

Tubular motor starts 1 x,

LED indicator flashes 4 x

LED indicator 

flashes 1 x

Press and hold program 
button for 11 sec.

Tubular motor 

starts 3 x

Release

programm button

LED indicator 

flashes 3 x

3T-MOTORS Tubular motors 12V

   |  Programming

 PROGRAMMING

Programming (pressing the buttons) must be carried out within 10 seconds. 
Otherwise the system returns to its original state.

Note: 

The following 3T-MOTORS transmitters do not have a P2 / Set Up button:

Radio wall transmitter 

WS1

Radio wall transmitter 

WS2

Radio wall transmitter 

WSE2

Radio timer 

WSTF1

Radio timer 

WSTF5

Radio mini transmitter 

FMSF

Button combination:

 

Press Up + Stop buttons simultaneously (FMSF / WS1 / WS2 / WSE2).
Press the Set and Mode buttons simultaneously (WSTF1 / WSTF5).

Summary of Contents for 3T-MOTORS 3T35-13

Page 1: ...0 12V F r Wellen ab 60 mm Motor type 3T35 13 12V F r Wellen ab 40 mm Motor type 3T45 50 12V F r Rundwellen ab 63 mm INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS INSTALLATION OPERATING INSTRUCT...

Page 2: ...SP50 Page 13 8 Shutter motor wiring Page 13 9 Setting the end positions Page 14 15 Mounting instructions for motor type 3T35 12V Page 16 Installation awning motor 12V SP50 Page 17 12 1 Preparation Pa...

Page 3: ...e of the drives must be laid internally in the empty conduit up to the junction box The local electrical regulations must be observed For the electrical connection of the tubular motors a 230 V 50 Hz...

Page 4: ...2 12 565 541 2 5 12 IP44 SP50 4260601762394 3T35 13 12V 13 40 7 5 5 35 13 36 12 595 575 2 5 12 IP44 SP50 4260601760550 Technical Data 2 3 1 5 4 6 7 8 9 SCOPE OF DELIVERY MOTOR TYPE 3T35 12V 1 Motor 2...

Page 5: ...doors 100 meters outdoors 595x92x32 mm can store max 20 transmitter channels compatible with all 3T radio transmitters SP50 3T45 20 12V 4260601762394 SP50 3T35 13 12V 4260601760550 Damage caused by im...

Page 6: ...r is paired Down button controls motor forward OK LED indicator flashes 1 x Tubular motor starts 1 x LED indicator flashes 4 x Tubular motor starts 1 x LED indicator flashes 4 x Connect the shutter mo...

Page 7: ...t Up Tubular motor starts 1 x LED indicator flashes 1 x Tubular motor starts 1 x LED indicator flashes 6 x LED indicator flashes 1 x a a b Change direction of rotation of radio motor Direction of rota...

Page 8: ...ED indicator flashes 1 x Tubular motor starts 1 x LED indicator flashes 4 x LED indicator flashes 1 x Press and hold program button for 11 sec Tubular motor starts 3 x Release programm button LED indi...

Page 9: ...For steel shafts with a width across flats of 40 mm SW40 only use shafts with an external fold Steel shafts with an internal fold will damage and destroy the motor Grinding marks of any kind on the m...

Page 10: ...versal bearing and Cover cap bearing 3T45 20 12V Clip bearing 3T35 12V Use one of the two motor bearings depending on the installation situation 1 2 3 4 5 6 7 8 9 10 11 Please note The motor can be in...

Page 11: ...clips Motor type 3T35 13 12V Installation with universal bearing or clip bearing Installation with universal bearing Push the motor with the square into the opening of the bearing and secure with cot...

Page 12: ...witch adapter fig 4 7 4 8 5 Mount bearings Remove old wall bearing on motor side left or right installation possible Mount motor bearing at this point 2 mounting options Universal bearing and cover ca...

Page 13: ...t the wall brackets on the wall with the supplied dowels and screws Attach the clip holder 1 to the wall or roof with suitable screws and dowels When doing so take the desired angle into account Snap...

Page 14: ...er cable to front The straight up and down arrows indicate the direction of rotation of the motor and shaft and thus show you for which end position the limit switch screw next to it is responsible De...

Page 15: ...be turned a little to hook in the suspension springs use the adjustment pin on the limit switch screw for the lower end position in the PLUS direction This causes the motor to turn the shaft stepwise...

Page 16: ...W40 only use shafts with an external fold Steel shafts with an internal fold will damage and destroy the motor Explanation Avoid overstressing and resulting premature aging of the motor by using the c...

Page 17: ...ews connecting the side bearing and the crank mechanism fig 3 3 Remove the side bearing from the support tube fig 3 4 Remove the crank mechanism fig 3 5 Attention Awning arms are under strong tension...

Page 18: ...e desired position with hexagonal wrench Mount the wall brackets on the wall with the supplied dowels and screws Attach the clip holder 1 to the wall or roof with suitable screws and dowels When doing...

Page 19: ...marking on the motor head Motor type 3T45 12V Power cable to rear Motor type 3T35 12V Power cable to rear Motor type 3T45 12V Power cable to front The straight up and down arrows indicate the directio...

Page 20: ...s If the motor is to continue moving turn the adjustment pin on the RETURN limit switch screw in the PLUS direction until the desired position is reached and the awning is fully retracted If the awnin...

Page 21: ...ch screw in the MINUS direction up to 100 turns depending on the motor type until the motor switches off Then allow the roller shutter shaft to rotate in the opposite direction and turn the other limi...

Page 22: ...Anforderungen der aufgef hrten EG EU Richtlinien erf llt 2006 42 EG Maschinenrichtlinie 2014 30 EU EMV Richtlinie 2011 65 EU RoHS Richtlinie 2012 19 EU WEEE Richtlinie angewandte Standards und Verordn...

Page 23: ...140 cm 160 cm Suspension spring Maxi Required when using roller shutter motors Maxi spring up to 65 mm profile height For roller shutter shaft SW60 Powder coated Anti burglary effect Pick up width 100...

Page 24: ...FOR SHUTTERS AND AWNINGS Service and Quality make the difference 3T Components GmbH Co KG Bahnhofstr 34 55578 Wallertheim Email info 3t components de Tel 49 0 6732 600 03 69 Fax 49 0 6732 600 54 30 ww...

Reviews: