background image

4

GENERAL SAFETY INSTRUCTIONS

IMPROPER USE

PROPER USE

 WARNING: Important safety instructions.  

  Follow all instructions as incorrect installation may result in serious injury.

 WARNING: The drive must be disconnected from the power source during cleaning, maintenance and replacement of parts.

 Danger to life from electric shock when working on electrical equipment. 

 The electrical connection, installation and commissioning of the receiver may only be carried out by qualified personnel.  

 Before installing the drive, remove all unnecessary cables and disable all devices,  

  that are not required for operation with power.

 The relevant regulations and guidelines must be followed without fail, to avoid damage to persons and objects.

 Observe safety instructions according to EN 60 335-2-97: The power supply cable of the drives must be laid internally.

 Installation according to DIN 18073: The roller shutter box cover must be easily accessible and removable.

 Installation according to EN 60335: Only switches / pushbuttons / switching devices with a minimum contact opening 

  of 3 mm may be used, furthermore the up and down direction must be interlocked against each other.

 When installing in damp rooms, observe regulations (VDE 0100, part 701 and 702).

 These drives can be connected in parallel without an isolating relay or central control.  

  In this case, the max. output power of the command transmitter (timer or otherwise) must be observed.

 Do not use defective devices: Never use defective equipment. 

  Periodically inspect the equipment for imbalance and signs of wear or damage to cables and suspension springs. 
  Do not use equipment if repair or touch-up is necessary. 
  There is a risk of personal injury and property damage due to electric shock or short circuit.

 Retain the instructions for future reference.

 Use tubular motors only for automating shutters.

 Only use original components and original accessories from the manufacturer. 

 The mains connection cable of the drives must be laid internally in the empty conduit up to the junction box. 

  The local electrical regulations must be observed.

 For the electrical connection of the tubular motors, a 230 V / 50 Hz 

  power connection with fuse must be available at the installation site.

 Inspect the installation frequently for imbalance and signs of wear or damage to cables and springs. 

  Do not use if repairs or adjustments are required.

3T-MOTORS Tubular motors

  |  Safety instructions

Please read these important safety instructions before commissioning!

Incorrect installation can cause serious personal injury and damage to property. 
The warranty claim expires in case of non-observance of this user information with all contained notes and regulations.
In case of non-observance of these instructions, the manufacturer or supplier shall not be liable for any personal injury or property damage incurred.

 SAFETY INSTRUCTIONS

This symbol indicates danger due to electrical energy. 

Danger to persons and objects may arise if the 

associated information is not observed!  

This symbol indicates information about general danger. 

Non-observance can mean danger to 

persons and objects!

This symbol indicates important information that can 

ensure safe and proper use of the device.

 Persons are to be instructed with the correct operation of the tubular motor. 

 The roller shutter movement must be monitored in order not to endanger persons. 

 Do not allow children to play with motor controls.

 Store the handheld transmitter in such a way that unintentional operation is prevented (e.g. by children playing).

 The device can be used by children aged 8 years and above and persons with reduced physical, sensory or mental 

  capabilities or lack of experience and knowledge, if they have been given supervision and instruction concerning use 
  of the appliance in a safe way and are aware of the hazards involved.

 Children are not allowed to play with the equipment.

 If the power supply cord of this device is damaged, it must be replaced by the manufacturer or its customer service 

  or a similarly qualified person to prevent hazards.

Summary of Contents for 3T-MOTORS 3T35-10B

Page 1: ...B For shafts from 40 mm 3T35 10B 3T35 13B www 3t components de WEEE Reg Nr DE 77028333 INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS INSTALLATION OPERATING INSTRUCTIONS Instructions and notes...

Page 2: ...ning motor Page 13 15 1 Preparation Page 13 2 Prepare motor for installation Page 13 3 Mounting awning motor Page 13 14 4 Awning motor wiring Page 14 5 Setting the end positions Page 15 Troubleshootin...

Page 3: ...account rail guidance of approx 10 Roller shutter area m x Weight roller shutter material m Weight roller shutter kg 10 Friction losses Required traction force kg Example PVC Roller shutter area 3 00...

Page 4: ...mains connection cable of the drives must be laid internally in the empty conduit up to the junction box The local electrical regulations must be observed For the electrical connection of the tubular...

Page 5: ...230 V 608 mm 587 mm 3 m 4 min IP44 4260601761380 3T45 20B 20 Nm 40 kg 6 m 4 7 m 161 W 15 U min 22 U 230 V 608 mm 587 mm 3 m 4 min IP44 4260601761397 3T45 30B 30 Nm 60 kg 9 m 7 m 200 W 15 U min 22 U 2...

Page 6: ...mm SW40 only use shafts with an external fold Steel shafts with an internal fold will damage and destroy the motor Grinding marks of any kind on the motor housing will void the warranty The inspection...

Page 7: ...5 B and 3T35 B Universal bearing and cover cap bearing 3T45 30B 3T45 40B clip bearing Use one of the two motor bearings depending on the installation situation 1 2 3 4 5 6 7 8 9 10 11 Please note The...

Page 8: ...g clip bearing Installation with universal bearing Push the motor with the square into the opening of the bearing and secure with cotter pin Installation with cover cap bearing Remove screws from meta...

Page 9: ...er fig 4 7 4 8 5 Mount bearings Remove old wall bearing on motor side left or right installation possible Mount motor bearing at this point 2 mounting options Universal bearing and cover cap bearing 3...

Page 10: ...cupied and must be insulated To do this push the enclosed wire end cap onto the wire end and press it together with crimping pliers or combination pliers Wire end cap 3T MOTORS Tubular motors Installa...

Page 11: ...g the end points with adjustment cable ESK Connect tubular motor to ESK Test the direction of rotation of the motor and change it if necessary To change the direction of rotation swap the up and down...

Page 12: ...SW40 only use shafts with an external fold Steel shafts with an internal fold will damage and destroy the motor Explanation Avoid overstressing and resulting premature aging of the motor by using the...

Page 13: ...e support tube fig 3 4 Remove the crank mechanism fig 3 5 Attention Awning arms are under strong tension 2 1 Limit switch adapter Motor head 2 2 2 3 Securing bracket 2 4 Click Shaft adapter Remove the...

Page 14: ...connection diagram of time switches differs from this circuit diagram Please refer to the corresponding manual for the connection diagram If the end points are set using the ESK do not connect the sw...

Page 15: ...eturn step by step Setting the end points with adjustment cable ESK Connect tubular motor to ESK Test direction of rotation Press Up button Awning moves IN Press Down button Awning moves OUT Change th...

Page 16: ...ler shutter motor page 11 awning motor page 15 the motor stops running after continuous operation The thermal protection switch of the motor has tripped After a cooling phase min 10 min the motor is r...

Page 17: ...nden Anforderungen der aufgef hrten EG EU Richtlinien erf llt 2014 35 EU Niederspannungsrichtlinie 2014 30 EU EMV Richtlinie 2011 65 EU RoHS Richtlinie 2012 19 EU WEEE Richtlinie angewandte Standards...

Page 18: ...3 5 mm Limit switch adapter Shaft adapter 3 8 m m Engine bearing Roll off bearing Enables the rolling shutter to unroll in case of defective motor or power failure Motor bearing for tubular motors wit...

Page 19: ...140 cm 160 cm Suspension spring Maxi Required when using roller shutter motors Maxi spring up to 65 mm profile height For roller shutter shaft SW60 Powder coated Anti burglary effect Pick up width 10...

Page 20: ...www instagram com 3tcomponents twitter com 3TComponents INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS Service and Quality make the difference 3T Components GmbH Co KG Bahnhofstr 34 55578 Walle...

Reviews: