background image

 

 

 

The Menu will be shown as below when set up program is activated. Choose 

Install Software(32bit

 

or 

Install Software(64bit)

  on the basis of your PC specs. 

※Please see 49 page to confirm your PC spec(32bit or 64bit) 

 

 

The image will be shown on screen as below. Please press 

Next

 

 

 

Summary of Contents for Anyty

Page 1: ...2 4GHzWireless Digital Microscope Comprehensive Operating Instruction ...

Page 2: ...which have been filmed by Anyty VIEW 30 P11 Spec 31 Manual of Anyty Series TV Model T1 How to charge Anyty Digital Microscope and LCD Monitor 32 T2 Switch on and Channel Harmonization 34 T3 Simple use of the product 37 T4 About operation of Anyty Digital Microscope 38 T5 Capturing still pictures 39 T6 Capturing movie 40 4 T7 Preview of images movies 41 T8 Deletion of images movies 43 T9 About all ...

Page 3: ...ectly at LED light source It could damage your Visual Acuity AVOIDING touching with wet hands DO NOT use the product with wet hands or the product in wet conditions It could lead to electric shock Decommissioning prohibited DO NOT decommission or modify the product It could lead to electric shock or fire hazard DO NOT use Organic Solvent on Resin body PLEASE note that using of alcohol or thinner f...

Page 4: ...ccessories in Microscope of magnification x 200 C Accessories in Microscope of magnification x 600 D Accessories in PC Model E Accessories in TV Model Operating Instruction This book Dedicated Case Model of magnification x 200 Three Lens covers For x60 200 For x80 150 For x100 Model of magnification x 600 Two Lens covers For x500 For x600 USB Receiver Product Stand AC USB Adaptor miniUSB Cable Mic...

Page 5: ...0 PC TV Model 3R WM401PCTV A B D E 6 2 4GHz Wireless Digital Microscope Set of Magnification x 600 PC TV Model 3R WM601PCTV A C D E 7 2 4GHz Wireless Digital Microscope Magnification of x 200 600 PCModel 3R WM461PC A B C D 8 2 4GHz Wireless Digital Microscope Magnification x 200 600 PC Model 3R WM461TV A B C E 9 2 4GHz Wireless Digital Microscope Full set of Magnification x 200 600 PC TV Model 3R ...

Page 6: ...t could last for 5 hours in full power condition Attention USB Charging Cable is for Microscope ONLY DO NOT use ANY other charging cable on it Charging Connector Charging Connector is on back of Microscope Dial Switch Power switch is on side face of Microscope Turn right until you hear the sound of click and the power will be turned on Turn left until the same sound is made The power will be off D...

Page 7: ...wsXPSP2 Vista Only for 32 bit CPU CPU above Pentium Ⅲ 600Mhz Optics Drive Essential Memory 256MB or more of Physical Memory Save Area 100MB or more HD space Connection Method USB1 1 2 0 Display Space 15 Inch XGA or more of display space Graphics Facility 16bit color or higher graphics facility Practical use authority Installation and using of the software may require ADM Recommended specs CPU Pent...

Page 8: ... connect Receiver to PC until installation is complete Please press Continue if User Account Control UAC is activated Insert Software CD into CD ROM The option will be shown as below if auto play is activated Press Autorun exe to start installation If Auto play is not activated Please double click My computer and RIGHT click CD ROM icon choose Open Then find Autorun exe and double click to start i...

Page 9: ...hen set up program is activated Choose Install Software 32bit or Install Software 64bit on the basis of your PC specs Please see 49 page to confirm your PC spec 32bit or 64bit The image will be shown on screen as below Please press Next ...

Page 10: ...9 License Agreement will be shown To continue installation please tick I accept Then click Next You could choose which folder to save it at next screen Normally click Next to start program installation ...

Page 11: ...t Receiver to USB port on PC with miniUSB cable Windows will detect the device automatically Installation will be done when the message shows as below The name will be shown in Device Manager as images shows as below To confirm by Device Manager please left click on Start and right click on Computer Then find Manage and left click on it ...

Page 12: ...11 During the Device installation please press Install this driver software anyway to continue installation ...

Page 13: ...t us at inquiry 3rrr co jp In case of using Windows8 32bit version to install insert install CD into CD ROM Then click the icon of computer on Desktop so the explorer will be shown Thirdly open click CD ROM icon and run Autorun exe In the follow up processing please go to page 7 of Installation of Windows7 Vista During the Device installation please press Yes to continue installation ...

Page 14: ...ep of use will be showing below Connect Receiver to PC and tune the channel Install a lens cover and turn the power on Launch software Anyty VIEW Adjust luminance of LED and Magnification dial As you press shutter button the image will be saved in the PC ...

Page 15: ...f 1 2 3 4 Switch of Channel Channel of 1 2 3 4 2 Then adjust the switch on Anyty Wireless Microscope as same number as on Receiver Switch of Channel Channel of 1 2 3 4 3 Once the channel has been tuned please turn dial switch right on Anyty Wireless Microscope Sound of click is the sign of power on Dial switch Dual purpose switch to Adjust luminance of LED and power ...

Page 16: ...ion when you take picture It will be the right focal length as the lens cover and object touch each other Trimming could be done with Magnification dial 2 To shoot under untouched and unknown magnification condition the lens cover could be removed from Microscope In the condition of untouchable between object and lens cover or in case of shooting without lens cover you could turn magnification to ...

Page 17: ...am and Desktop In some case icon would not be established on desktop Desktop icon Double click to launch Anyty VIEW You are also able to open it from Start All Program 3R Anyty VIEW 40101 Please left click 3R Anyty VIEW 40101 to launch it Main Window Once the program is launched the Main window will be shown ...

Page 18: ... still picture Filming Stop Continuous shooting of still picture Attach to E mail Save Thumbnail of image and movie Icon of summary of image movie Data of image and movie will be shown as thumbnail on left side of main window Click the icons shown above to switch between thumbnail of images and movies Data of image movie will be saved in 3R files in My Document so you are able to browse those data...

Page 19: ...file through using Save icon No frame Taking still picture Three ways of taking still picture Press icon on tool bar Press keyboard button F2 Press round button on Microscope Image data will be saved in folder 3R Files in My Document as name of Still pic_year month day hour minute second_ magnification _number bmp Magnification will be the figure that you have entered in main window See scale Magn...

Page 20: ...lly please use it under default condition Reference Analogue TV Approx 30 fps Movies on Mobile phone 15 24fps Time limit Check the box to set filming time in seconds and stop filming automatically Click to start or stop filming manually When stop filming the data will be saved automatically Little error could be possible depend on condition or codec Codec You are able to choose different kind of c...

Page 21: ...one in time you have set after current shooting Capture Set how many pictures you want to take and save File size It shows the size of pictures based on your settings Attach to Email Select thumbnail of images or movies and press this icon or choose Attach to email from Menu bar After that the defaults Email software in your PC will be opened automatically with selected data adjust Saving Select t...

Page 22: ... or make it display scales Capture Contains the same functions of icons on the Main Window Taking still picture or filming movie and taking Continuous picture Help Display the software version and our website Change the language of the software Two kinds of resolution of saved pics Changing options of display see page 22 Mainly changes the measurement functions settings Shows scale and circle etc ...

Page 23: ...ings Cross line Display a cross line at the center of screen Scale Display scale horizontally and vertically It will overlap cross line Dial gauge will not change due to change of magnification Circle Use center of screen as a baseline to display circle Change resolution of the saving picture Adjust Brightness of captured image Adjust Contrast of captured image Adjust Saturation of captured image ...

Page 24: ...e magnification dial gauge and the number printed on lens cover to enter the measuring function will calculate the data automatically based on figure in the blank go to page 26 See Magnification dial gauge and enter Change of direction Click the icons on the menu bar to change screen direction Flip horizontal Flip Vertical Color modification Click icons which have functions of Negative Vampix and ...

Page 25: ...nu bar are for measuring Each icon has its specific measurement method Icons of measurement Operation of Measurement functions e g Linear size Click the icon on menu bar Measurement of Linear size Negative and Vampix Color Invalidation Icons choose two ...

Page 26: ...p part of the L when you want to measure height of it Click twice at the point of red arrow At last click anywhere you want to display the value It will be displayed Please click Save icon to save the value you have measured if you want Click once more and the measured value will be displayed ...

Page 27: ...some specific measurement Additions and Corrections Use Additions and Corrections to calculate more accurate value Steps are shown below First capture attached simple scale ore micro meter with Microscope Then click the icon on top right side as picture shows below Next please click two side of the scale that already clear of size same as calculate Linear size The window shows as below will be dis...

Page 28: ...newal the measurement or delete it please click the icon at right side of correction icon Click Undo to delete previous measurement Also click Delete All to delete all value you have entered Pen settings Setting of measurement functions Click Setting in setting on menu bar or click setting in icon to display Pen setting menu You are able to set font of letter Linear size etc ...

Page 29: ...amed picture which are captured by Anyty VIEW only Save You are able to save the picture as another name after editing Paint You are able to paint line and figure in picture Measure Enter magnification to enable measurement and editing Operation steps are same as in page 24 Pen setting You are able to change color of painting and line of measurement Screen and control are same as manual on page 27...

Page 30: ...ndo Enter magnification at capture period You must do this when you measure size Calibration Use this to improve accuracy of measurement To understand control step please see page 26 Change font of texts Font will be different between vertical writing and horizontal writing Press OK when finish entering Left click to insert text on part of images where you wish to put ...

Page 31: ...30 P10 Playing captured movies with Anyty Double click the movies you have captured in main window to open movie player and start playing it ...

Page 32: ...2 4Ghz wireless 4 channels Transmitter receiver Transmission distance Approx 5m PC interface receiver USB 2 0 1 1 Magnification x200 x10 200 15 inch LCD screen Magnification x600 x450 600 15 inch LCD screen Power source Charging Li ON Battery Full charge time Approx 3 hours Max working time Maximum 5 hours Life Approx 500 cycle Power consumption Maximum 0 75W Focus range x200 model 8 300mm x600 mo...

Page 33: ...uring charging period dial switch flashes blue Charging period will be approx 3 hours Maximum 5 hours of working time in full power condition Attention USB charging cable is specialized to Microscope Please DO NOT use it for charging LCD monitor It could be the cause of breakdown or heating Charging connector Dial switch Turn it right until it sounds click and the power will be on Charging Blue fl...

Page 34: ...he charging is complete Charging time will be about 3 hours It lasts about maximum 2hours in full power condition Attention AC adaptor is only for LCD Monitor Please DO NOT use it on Microscope It could be the cause of breakdown or heating During charge period Red light Charge complete Light off Press power button at top side of LCD Monitor to turn the power on Light on top left side will be green...

Page 35: ...firm that the MicroSD card is inserted properly Then choose one of four channels After tuning turn the dial switch right on the Microscope until it sounds click to turn on the power Dial switch Dual purpose switch to Adjust luminance of LED and power Then turn of the power of the LCD Monitor ...

Page 36: ...ll shows screen as described below Channel will be shown on top right side of the screen Radio Channel Press button to do the tuning in case of mismatching channel button Setting is complete if the picture is displayed ...

Page 37: ...n Setting menu will be displayed Select SYSTEM SETTING with button and press OK to confirm Each setting will be displayed Select Language with button and press OK to confirm The language will be set Select English with button and press OK to confirm Press button 3 times to back to main screen That is all about language setting ...

Page 38: ...more details about operation steps Turn the both power of Microscope and LCD monitor on Load lens cover and adjust magnification and focal point Press button on the monitor to select image movie to capture Press OK button to save the data ...

Page 39: ...g figure of magnification when you take picture It will be the right focal length as the lens cover and object touch each other Trimming could be done with Magnification dial 2 To shoot under untouched and unknown magnification condition the lens cover could be removed from Microscope In the condition of untouchable between object and lens cover or in case of shooting without lens cover you could ...

Page 40: ...of LCD Monitor first and press button It will be still picture mode Saving still picture Press OK button at left side of the LCD monitor in Saving Still Picture Mode to save current screen The icon of MicroSD will be marked F if the SD card is full Residual amount of a battery Icon of still picture mode Channel Icon of Micro SD card Savable number of pictures Current Time Time stamp ...

Page 41: ...of the LCD monitor in Movie capture mode and recording will be starting During capturing period a round icon at top of the screen will flash Capturing time will be shown at bottom right side of the screen Press OK again to stop recording The icon of MicroSD will be marked F if the SD card is full Residual amount of a battery R Icon of Micro SD card Possible recording time or recording time Current...

Page 42: ... Press button to select and OK to confirm Then the index of selected file will be shown Press to choose Data of what you want to view and press OK to confirm Difference between Image Movie data Data with double quotation mark Image data Data with no quotation mark Movie data Preview images Press OK to display the image on screen Press OK again to back to previous screen Movie data Image data ...

Page 43: ...42 Preview of movies Press OK to play the movie Halt Press OK when the movie is playing Forwarding Press when the movie is playing Rewind Press when the movie is playing End Press to end ...

Page 44: ...43 T8 Delete images movies Select the file that you want to delete with button Then press button for 2 seconds It will ask you if you confirm Select Yes and press OK to delete the file ...

Page 45: ...mally unnecessary to change from NTSC to another Select SYSTEM SETTING in setting menu Select Video System Select one from NTSC and PAL and press OK to confirm Formatting All data in SD card will be deleted after formatting Select SYSTEM SETTING in setting menu Select Format Choose Yes to format MicroSD card Initialize the config All setting will be reset after initializing the config Select SYSTE...

Page 46: ...e from 10 to 30fps Time stamp Changing having time stamp or not Select RECORDER SETTING in setting menu Select Time Stamp Select one from ON OFF and press OK to confirm Capturing type You are also able to switch between still video from setting Select RECORDER SETTING from setting menu Select Recording Type Select one from Still Video and press OK to confirm Preview You are also able to find previ...

Page 47: ...of the internal date and time Select Date Time in setting menu Set Year month day and Hours Use Up and Down button to change value and move to the next item by the Confirm button Push the menu button if you have set all values and finish ...

Page 48: ... Monitor on TV Please connect picture input of TV to the picture output of the LCD monitor with an attached video cable A picture will be output to TV without a screen being displayed when you switch on the LCD monitor Use USB cable to connect Optional Please use miniUSB cable sold at market to connect with PC when you want to view data on PC Connect LCD Monitor and PC with miniUSB cable and turn ...

Page 49: ...yed it with a attached monitor of the TV model will be different Thank you for your understanding beforehand LCD 3 5 inches TFT LC Resolution 320x240 Video format PAL NTSC Frequency 2414MHz 2432MHz 2450MHz 2468MHz Power supply 5VDC Consumption current max 500mA Charging time About 3 hours Working time Maximum 2 hours Resolution of still video 640x480 Movement size 27MB min Frame rate Maximum 30fps...

Page 50: ... the microscope it may have an influence on operation of the microscope E When you could not operate an LCD monitor in TV model please push the reset button of the backside with a former thin thing and switch it on again F Please try the following operation to confirm the number of the bits of the system by Windows7 and Vista Please right click the Computer and click Property Please look at System...

Page 51: ...50 Manufactured and sold by 3R SYSTEMS CORP HQ No 5 8 11 Naka Hakata ku Fukuoka City Japan Official website 81 92 441 4056 81 92 441 4077 ...

Reviews: