background image

How it works:

1. As water arrives the level builds up and 
  is equally distributed across the cascade

2. Pre-cleaning through the cascades. 
  Largest dirt particles are led across the
  primary filter cascades directly to the 
 stormwater.

3. Pre-filtered water then flows over 
  the secondary filter sieve 
  (mesh size 0.65 mm). Due to the 
  special mesh structure of the sieve,
  any dirt washes directly into the 
  stormwater. Very low maintenance.

Installation advice 3P Volume Filter combi:

•  Connections to the 3P Volume Filter VF1 combi can be made with universal connectors.
•  Rainwater enters through the upper inlets, at DN 100. For roof areas up to 175 m² 
  connect from either right or left.
•  For roof areas above 175 m² we recommend you connect from both sides, in order to obtain   
  the maximum filter efficiency.
•  Saw off 1 cm from the outside of the selected inlet(s).
•  Cleaned water is led via the outlet at DN 125 to the storage tank.
•  Dirty water goes via the outlet at DN 125 to waste.

4. Cleaned water flows to storage

5. Dirt goes to the stormwater

Installation of the 3P Volume Filter VF1 combi

cleaned water to
storage tank DN 100

inlet rainwater 
DN 100

inlet rainwater
DN 100

dirty water to storm-
water DN 125

1

2

3

4

5

Reviews: