background image

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

Rack-mounted

 

Step 1 

Select the device mounting location to ensure 
enough size. 

Step 2 

Put the device on the plane plate of the rack, and 
install the left and right lugs on the rack with 4 
screws. 

        

 

Step 3 

Check and confirm the product is mounted firmly on 
the rack, mounting ends. 

Disassembling Device

 

Step 1 

Power off the device. 

Step 2 

Unscrew the fixed mounting lug screw on the rack. 

Step 3 

Shift out the device from rack, disassembling ends. 

Notice before power on: 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
then plug the power supply plug contact and power on. 

 

Power OFF operation: First, remove the power plug, 
then remove the wiring section of terminal block. Please 
pay attention to the above operation sequence.

 

Power Supply Connection

 

The device provides 3-pin 5.08mm pitch 
DC power terminal block, power supply 
range: 24VDC (12-36VDC).

 

Relay Connection

 

This device provides 3-pin 5.08mm pitch 
relay terminal blocks,  which are a set of 

normally open contacts of the device alarm relay. They are 
open circuit in the state of normal non alarm, closed when any 
alarm information occurs. For example, they are closed when 
powered off, and send out alarm. The series of switch support 
1 relay alarm information output that can output DC power 
supply alarm information or network abnormality alarm. It can 
be connected to alarm light or alarm buzzer or other switching 
value collecting devices, which can timely inform operators 
when the alarm occurs. 

Communication Interface Connection

 

This device provides 24 10/100/1000Base-T(X) 
interfaces, the interface type is M12 X-Coded 
8-Pin slot (female), therein G1-G8 supports 
PoE function, support IEEE802.3at/af 

self-adaption. The pin definitions of M12 are shown as follows: 

Pin No.  Pin Definition 

Description 

BI_(DA+) 

Positive bi-directional data 
of Gigabit Ethernet group 1 

BI_(DA-) 

Negative bi-directional data 
of Gigabit Ethernet group 1 

BI_(DB+) 

Positive bi-directional data 
of Gigabit Ethernet group 2 

BI_(DB-) 

Negative bi-directional data 
of Gigabit Ethernet group 2 

BI_(DD+) 

Positive bi-directional data 
of Gigabit Ethernet group 4 

BI_(DD-) 

Negative bi-directional data 
of Gigabit Ethernet group 4 

BI_(DC-) 

Negative bi-directional data 
of Gigabit Ethernet group 3 

BI_(DC+) 

Positive bi-directional data 
of Gigabit Ethernet group 3 

Console Port Connection

 

The device provides 1 program debugging port based on 
RS232 serial port which can conduct device CLI command 

management after connecting to PC. The interface adopts 
RJ45 port, the RJ45 pin definition as follows: 

Pin No. 

Pin Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

The device provides LED indicators to monitor its operating 
status, which has simplified the overall troubleshooting 
process. The function of each LED is described in the table 
below: 

LED 

Indicate  Description 

PWR 

ON 

Power is connected and running 
normally 

OFF 

Power supply is disconnected or 
running abnormally 

ALM 

ON 

Port link has alarm 

OFF 

Port link has no alarm 

RUN 

ON 

The device self-check hasn't 
finished or the device is abnormal. 

OFF 

The device is powered off or the 
device is abnormal. 

Blinking 

Blinking about 1 time per second, 
system is running normally 

Link/Act 

ON 

Ethernet port has established a 
valid network connection 

Blinking 

Ethernet  port  is in an active 
network status 

OFF 

Ethernet port has not established 
valid network connection 

PoE 

ON 

POE port is powering other 
devices normally 

OFF 

POE is disabled or disconnected 

Logging in to WEB Interface

 

This device supports WEB management and configuration. 
Computer can access the device via Ethernet interface. The 
way of logging in to device’s configuration interface via IE 
browser is shown as below: 
Step 1 

Configure the IP addresses of computer and the 

Reviews: