RS232, which could be connected to PC for device CLI
command management. The interface adopts RJ45 port. The
pin definitions of RJ45 are as follows:
No.
2
3
5
Definition
TXD
RXD
GND
【
Checking LED Indicator
】
This device provides LED indicators for monitoring the work
status of the device, which has simplified the troubleshooting
process comprehensively. The function of each LED is
described in the table as below:
LED
Status
Description
PWR
ON
PWR is connected and
running normally
OFF
PWR is disconnected and
running abnormally.
ALARM
ON
Power supply, port link
alarm
OFF
Power supply, port link
without alarm
RUN
ON
The device is powered on
or the device is abnormal.
OFF
The device is powered off
or the device is abnormal.
Blinking
Blink 1 time/s, system is
running well.
Link/Act
(X1-X8/G1-G4)
ON
Ethernet port connection is
active.
Blinking
Data transmitted
OFF
Ethernet port connection is
inactive.
POE(X1-X8)
ON
POE port is powering other
devices.
OFF
POE port is not powering
other devices.
【
Logging in to WEB Interface
】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device
’s configuration interface via IE
browser is shown as below:
Configure the IP addresses of computer and the
Step 1
device to the same network segment, and the
network between them can be mutually accessed.
Enter device
’s IP address in the address bar of the
Step 2
computer browser.
Enter device
’s username and password in the login
Step 3
window as shown below.
Click
“OK” button to login to the WEB interface of
Step 4
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default username and password of the device is
“admin”.
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【
Specification
】
Panel
100M M12
10/100Base-T(X), M12 (Female),
4-Pin D-Coded, automatic flow
control, full/half duplex mode,
MDI/MDI-X automatic detection;
Optional PoE output.
Gigabit M12
10/100/1000Base-T(X)
,
M12(Female)
,
8-Pin A-Coded
automatic flow control, full/half
duplex mode, MDI/MDI-X
automatic detection; support
Bypass function
POE
PoE power supply pin
:
1, 2 are
negative
;
3, 4 are positive
Console port
CLI command management port,
RJ45
Alarm interface
3-pin 5.08mm pitch terminal
blocks, 1 relay alarm information
output,
the
current
loading
capability is 5A@30VDC or
10A@125VAC
Indicator
Power indicator, run indicator,
interface
indicator,
alarm
indicator POE indicator (only for
PoE product)
Exchange attributes
Backplane bandwidth
12.8G
Packet buffer size
3Mbit
MAC table size
8K
Power supply
Input power supply
110VAC/DC (100~240VAC/DC)
Input terminal
3-pin 5.08mm pitch terminal
blocks
Consumption
TNS5500-4GT-8T
No-load
Full-load
:
14.85W@110VDC