background image

stability, mounting ends. 

 

Wall-mounted Device Disassembling

 

Step 1 

Device power off. 

Step 2 

Unscrew the screw on the wall about 2mm. 

Step 3 

Lift the device upward slightly; take out the device, 
disassembling ends. 

Notice before powering on: 

 

Power ON operation: First insert the power supply 
adapter into the device power supply interface, and then 
plug the power supply plug and power on. 

 

Power OFF operation: first, remove the power plug, and 
then remove the wiring section of the adapter. Please 
pay attention to the above operation sequence. 

Power Supply Connection

 

 

DC power supply 

Power interface adopts 3-pin 5.08mm pitch 
terminal block. Input voltage: 12~36VDC. 

 

Serial Port Connection

 

 

RS-232 DB9 interface 

This product provides an RS232 DB9 interface, 
interface type is RS232 DB9. The pin 
definitions as shown in the following table: 

PIN 

6  7  8  9 

RS-232 

-

 

TXD

 

RXD

 

-

 

GND

 

-

 

-

 

-

 

 

 

RS-485/422 5-pin terminal block 

The product provides 2 RS-485/422 interfaces with 5-pin  
5.08mm pitch terminal block. When the device is used as the 
RS-485/422 relay, one interface is the proximal interface and 
the other is the remote interface. 

 

 

 

The pin definitions as shown in the following table: 

T+/485+ 

RS-422 sends positive, or RS-485 sends 
positive 

T-/485- 

Rs-422 sends negative, or RS-485 sends 
negative 

GND1 

Signal ground 1 (proximal end )

 

GND2 

Signal ground 2 (remote end) 

R+ 

RS-422 receive positive 

R- 

RS-422 receive negative 

Note:

   

The device cannot be used as a signal converter and relay at the 
same time, users have to choose between the two. 

 

When used as a RS-485/422 relay, the local device is 
connected to RS-485/422 terminal 1 (corresponding to 
GND1), and the remote device is connected to 
RS-485/422 terminal 2 (corresponding to GND2). 

 

When used as an RS-232/485/422 interface converter, 
use the RS-485/422 terminal 2 (the corresponding 
ground is GND2). 

Checking LED Indicator

 

The device provides LED indicators to monitor the device 
working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 

table as below: 

LED 

Indicate 

Description 

PWR 

ON 

PWR is connected and running 
normally 

OFF 

PWR is disconnected and running 
abnormally 

RXD 

ON 

RS-485/422 is receiving data. 

OFF 

RS-485/422 has no received data 

TXD 

ON 

RS-485/422 is transmitting data 

OFF 

RS-485/422 is not transmitting data or 

transmitting data abnormally 

Specification

 

Panel 

 

RS-232

 

DB9 interface, female hole 
type

 

RS-485/422 

 

5-pin terminal block, with 
5.08mm pitch

 

Indicator 

Power indicator, serial port 
transmission and receiving 
data indicator 

Power Supply

 

 

Input power supply

 

12~36VDC 

 

Access terminal block 

3-pin terminal block, with 
5.08mm pitch

 

Power Consumption 

 

Static power consumption 

≤150mA

 

Dynamic power 
consumption (average 
value) 

≤30mA

 

Working Environment 

 

Working temperature

 

-10~75

 

Storage temperature

 

-40~75

 

Reviews: