3onedata SW4485I Quick Installation Manual Download Page 2

 

 

Check if the DIN-Rail mounting kit is installed firmly. 

Step 1

 

Insert the bottom of DIN-Rail mounting kit (one side 

Step 2

with spring support) into DIN-Rail, and then insert 
the top into DIN-Rail. 

Tips: 
Insert a little to the bottom, lift upward and then insert 
to the top. 

 

Check and confirm the product is firmly installed on 

Step 3

DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

】 

 Device 

power 

off. 

Step 1

 

After lift the device upward slightly, first shift out the 

Step 2

top of DIN-Rail mounting kit, and then shift out the 
bottom of DIN-Rail, disassembling ends. 

Notice before power on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
and then plug the power supply plug contact and power 
on. 

 

Power OFF operation: First, remove the power plug, 
and then remove the wiring section of terminal block. 
Please pay attention to the above operation sequence. 

Power Supply Connection

 

The product provides 3-pin 7.62mm pitch 

terminal blocks, in which 1 and 3 are power 

input and 2 is grounding. The power supply has the function of 

non-polarity and anti-reverse connection, and the device can 

still work normally after the reverse connection. 

Voltage range: 12VDC~48VDC. 

Serial Port Connection

 

 

Lower device RS-485   

The device provides 4 RS-485 

lower device interfaces, the 

interface type is 10-pin 

5.08mm pitch terminal block, support 15kV electrostatic 

protection, 2kVAC isolation protection. The pin definitions as 

shown in the follow table: 

PIN

 

Definition

 

Note

 

1. GND 

Signal 

ground 

2. 

4D+ 

RS-485 positive signal input 

(out) terminal 

3. 

4D- 

RS-485 negative signal input 

(out) terminal 

4. 

3D+ 

RS-485 positive signal input 

(out) terminal 

5. 

3D- 

RS-485 negative signal input 

(out) terminal 

6. GND 

Signal 

ground 

7. 

2D+ 

RS-485 positive signal input 

(out) terminal 

8. 

2D- 

RS-485 negative signal input 

(out) terminal 

9. 

1D+ 

RS-485 positive signal input 

(out) terminal 

10. 

1D- 

RS-485 negative signal input 

(out) terminal 

 

RS-232/485 serial port of the upper device 

The device provides 1 RS-232/485 upper 

device port, the interface form is 5-pin 

5.08mm pitch terminal block, supports 15kV electrostatic 

protection, 2kVAC isolation protection. The pin definitions as 

shown in the follow table: 

PIN 

Definition 

Note 

1. 

D+ 

RS-485 positive signal input (out) 

2. 

D- 

RS-485 negative signal input 

3. GND RS-232 

signal 

ground 

wire 

4. 

TxD 

RS-232 data sending terminal 

5. 

RxD 

RS-232 data receiving terminal 

Checking LED Indicator

 

The device provides LED indicators to monitor the device 
working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 
table as below: 

LED 

Indicate 

Description 

PWR 

ON 

PWR is connected and running 
normally 

OFF 

PWR is disconnected and running 
abnormally 

1-4 

ON 

The device is normally powered on, 

and the corresponding interface 

from D1 ~ D4 is in the state of 

receiving/sending data 

Blinking 

D1~D4 corresponding interfaces 

are sending/receiving data 

OFF 

Fault warning: the device is not 

powered on or the device is 

normally powered on, D1~D4 

corresponding interface signal line 

is inversely connected 

TX 

Blinking 

transmitting data 

OFF 

No data transmission 

RX 

Blinking 

receiving data 

OFF 

No data receiving 

Reviews: