speed automatically, zero delay time,

Transfer distance: RS-485/422 side: 1.2Km(9600bps)

RS-232 side: no less than 5m

Fiber optic:20,25,40,60,80,100,120km(SM),

2,5 km(MM) optional

Max number of drops:RS385/422: 128drops
Fiber connector: 2

×

SC, 2

×

ST, 2

×

FC optional

Wavelength:1310nm
Fiber optic cables: Single Mode:8.3/125,8.7/125,9/125 or 10/125 um

Muti-Mode:50/125,62.5/125 or 100/125 um

600W surge protection;1500W static protection
Power input: +9V~36VDC power supply input(2 bit terminal block)
Dimensions: 100.0mm

×

69mm

×

22.0mm

Operating temp: -25°C to70°C
Storage temperature: -40 to 85°C
Operating humidity: 5% to 95%(no condensation)
Warranty: 3 years
Approvals: FCC,CE,RoHS approvals

Applications:

Figure 1: Extending the RS232 data distance

Figure 2: Extending the RS485 data distance

Figure 3: Extending the RS422 data distance

Installation:

Model277 provides DIN-rail and wall mounting two types of
installation.

Wall mounting installation

DIN-Rail Installation

Troubleshooting instructions:

1. Electric port and optic port inconnection, insert the power
supply, PWR light, RXD light.

2. Use optic fiber short the optic port IN and OUT, RXD OFF.
3. If the up stream port is RS-232, connect the up stream port to
PC RS-232 port correctly, Using “Start” → “accessory”
→ “communication”, open the typical termianl, choice the
correct COM port and 9600bps speed

shorting the optic IN

and Out, input character in the typical termianl window, you
will see the data indicate, if you donot see the data indicate,
the products is failure.

Model277 FAQ:

LED indicator OFF

1.Power supply insert incorrect
2.Choice incorrect power supply( 9~36VDC)

LED indicator instruction

1.PWR ON: Product work normally
2.TXD indicator flash: optic port transfer data
3.RXD indicator flash: optic port receive data
4.RXDON: optic connection incorrect

electric port in connection,

used to optic port alarm indicator

Communication failure

1.Using incorrect power supply
2.Optic port or electric port connection incorrect.
3.Optic fiber port do not inosculate to the equipment interface
4.The equipment come from different supplier
5.Single-mode optic fiber uses multi-mode equipment or

multi-mode optic fiber uses single-mode equipment

6.The optic fiber connector is incorrect, high error code,

attenuation large.