3onedata IPS716-2GC-4POE User Manual Download Page 3

- 3 - 

Gigabit MDI (straight-through cable) 

 

Gigabit MDI-X (Cross over cable) 

 

MDI/MDI-X  auto connection makes switch easy to use for 
customers without considering the type of network cable. 

 
1000BaseSFP fiber port(mini-GBIC) 

1000BaseSFP  fiber port adopts gigabit mini-GBIC  transmission, 
can choice different SFP module according to different transfer 
distance. Fiber interface must use for pair, TX port is transmit side, 
must connect to RX (receive side). The fiber interface support loss 
line indicator. 

Suppose

:  If you make your own cable, we suggest  labeling  the 

two sides of the same line with the same letter (A-to-A and 
B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 

 

LED Indicator

 

LED indictor light on the front panel of product, the function of 
each LED is described in the table as below. 

System indication LED 

LED 

State 

Description 

PWR 

(1~2) 

ON 

Power is being supplied to power 
input PWR input 

OFF 

Power is not being supplied to 
power input PWR input 

RUN 

ON/OFF  System is not running well 
Blinking  System is running well 

ALM 

ON 

When the alarm is enabled, power 
or the port’s link is inactive. 

OFF 

Power and the port’s link is active, 
the alarm is disabled. 

Link/ACT 

(1~4/G1~G2) 

ON 

Port connection is active 

OFF 

Port connection is not active 

Blinking  Data transmitted 

POE 

(1~4) 

ON 

The PoE device is connected by 
IEEE802.3af/at standard 

OFF 

No PoE power output or no PoE 
connected PoE devices 

 

Installation

 

Before installation, confirm that the work environment meet the 
installation require, including the power needs and abundant 
space. Whether it is close to the connection equipment and other 
equipments are prepared or not.   
1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 
3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

4. Power: 48VDC power input 

5. Environment: Working temperature: -40

75

 

Storage temperature: -40

85

 

Relative humidity: 5%

95% 

DIN Rail Installation 

In order to use in industrial environments expediently, the product 
adopt 35mm DIN-Rail installation, the installation steps as below: 

1.

 

Examine the DIN-Rail attachment 

2.

 

Examine DIN Rail whether be firm and the position is 
suitability or not. 

3.

 

Insert the top of the DIN-Rail into the slot just below the 
stiff metal spring. 

4.

 

The DIN-Rail attachment unit will snap into place as shown 
below. 

 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.

 

It is needed to check whether the type, quantity and 
specification of cable match the requirement before cable 
laying; 

2.

 

It is needed to check the cable  is damaged or not, factory 
records and quality assurance booklet before cable laying; 

3.

 

The required cable specification, quantity, direction and 
laying position need to match construction requirements, and 
cable length depends on actual position; 

4.

 

All the cable cannot have break-down and terminal in the 

Summary of Contents for IPS716-2GC-4POE

Page 1: ...s shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial PoE switch ⅹ 1 User manual ⅹ 1 Documentation and software CD ⅹ 1 DIN Rail mounting kit ⅹ 1 Warranty card ⅹ 1 Feature Support IEEE802 3 IEEE802 3u IEEE802 3x IEEE802 3z ab IEEE802 1Q IEEE802 1p IEEE802 1D W Compatible with both IEEE802 3at 30W...

Page 2: ...pply from one of the DC power inputs The user can connect the relay to the lamp indicate or buzzer alarm to remind the relevant staff Console port This product provided 1pcs procedure test port based in serial port It adopts RJ45 interface located in top panel can configure related command through RJ45 to DB9 female cable DIP Switch Top panel provided 4 bits DIP switch to do function configure ON ...

Page 3: ...nected PoE devices Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is close to the connection equipment and other equipments are prepared or not 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in intense EMI 2 Examine the cables and plugs that installation require...

Page 4: ...pps 1000M forward speed 1488100pps Transmit mode store and forward System exchange bandwidth 7 8G MAC address table 8K Memory 1M Interface Fast Ethernet Port 10Base T 100Base TX auto speed control Half full duplex and MDI MDI X auto detect Gigabit Combo port 1000Base X SFP slot or 10 100 1000Base T X Console port RS 232 RJ45 connector Alarm port 2 bit 7 62mm terminal block 1 channel relay alarm ou...

Reviews: