Dimension

 

The series of products size is same, and the type of the Ethernet 
interface is different. Unit (mm) 

 

Power supply input

 

 

The product top panel provided 4 bit power supply input terminal 
block, support DC input. DC power supply input supported 
redundancy function, provided PWR1 and PWR2 power input, 
can use for single, and can connect 2 separately power supply 
system, use 1 pair terminal block connect the device at the same 
time. If one of the power systems broke, the device can work 

un-interruptible.  Built-in overcorrect protection, Reverse 
connection protection. Voltage input range is 48VDC (terminal 
block defined as: V1-

V1+

V2-

V2+). The power supports 

reverse connection protection. 

Relay connection

 

 

Relay access terminals in the top panel of the device. Between the 
two terminal relay, as an open circuit state in normal non alarm 
state, when there is power alarm information to the closed state. 
The two terminal block connector are used to detect power failure 
and network anomaly. The two wires attached to the Fault 
contacts form a  closed  circuit when the device port connection 
disconnect or  has lost power supply from one of the DC power 
inputs. The user can connect the relay to the lamp indicate or 
buzzer alarm to remind the relevant staff. 

Console port

 

This series product provided 1pcs procedure test port based in 
serial port. It adopts  RJ45 interface, located in top panel, can 
configure related command through RJ45 to DB9 female cable. 

 

DIP Switch

 

 

Top panel provided 4 bits DIP switch to do function configure 
(ON to enable effective), 1 is data upgrade testing  (8POE) / 
reserved (4POE). 2 is recovery default factory. 3 is for upgrade. 4 
is reserved. Please power off and power on when you change the 
status of DIP switch.

 

Communication connector

 

10/100/1000BaseT(X) Ethernet port 

The pinout of RJ45 port display as below, connect by UTP or STP. 
The connect distance is no more than 100m. 1000Mbps is used 

120Ω of  UTP 5e; 100Mbps is  used  120Ω  of  UTP  5; 10Mb

ps is 

used 120Ω of UTP 3, 4, 5.

 

 

RJ 45 port support automatic MDI/MDI-X operation. That can 
connect the PC, Server, Converter and HUB. Pin 1, 2, 3, 4, 5, 6, 7, 

8  Corresponding  connections  in  MDI.  1→3,  2→6,  3→1,  4→7, 
5→8, 6→2, 7→4, 8→5, are used as cross w

iring in the MDI-X 

port of Converter and HUB. In MDI/MDI-X, 100/1000Base-TX 
PIN defines is as follows: 

PIN 

MDI 

MDI-X 

BI_DA+/TX+  BI_DB+/RX+ 

BI_DA-/TX- 

BI_DB-/RX- 

BI_DB+/RX+  BI_DA+/TX+ 

BI_DC+/— 

BI_DD+/— 

BI_DC-/— 

BI_DD-/— 

BI_DB-/RX- 

BI_DA-/TX- 

BI_DD+/— 

BI_DC+/— 

BI_DD-/— 

BI_DC-/— 

Note: 10Base-T/100Base-TX, “TX±”transmit data±, “RX±”receive data±, 

“—”not use. 

10/100Base-T(X) MDI (straight-through cable) 

 

Summary of Contents for IPS7110-2GC-8POE

Page 1: ...ms If any of these items are missing or damaged please contact your customer service representative for assistance Industrial PoE switch ⅹ 1 User manual ⅹ 1 Documentation and software CD ⅹ 1 DIN Rail mounting kit ⅹ 1 Warranty card ⅹ 1 Feature Support IEEE802 3 IEEE802 3u IEEE802 3x IEEE802 3z ab IEEE802 1Q IEEE802 1p IEEE802 1D W Compatible with both IEEE802 3at 30W and IEEE802 3af 15 4W Supports ...

Page 2: ...circuit when the device port connection disconnect or has lost power supply from one of the DC power inputs The user can connect the relay to the lamp indicate or buzzer alarm to remind the relevant staff Console port This series product provided 1pcs procedure test port based in serial port It adopts RJ45 interface located in top panel can configure related command through RJ45 to DB9 female cabl...

Page 3: ...t connection is active OFF Port connection is not active Blinking Data transmitted POE 1 4 8 ON The PoE device is connected by IEEE802 3af at standard OFF No PoE power output or no PoE connected PoE devices Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is close to the connection equipment and...

Page 4: ...user name access system SW Ring Support Single Couple Chain Dual homing Exchange attribute 100M forward speed 148810pps 1000M forward speed 1488100pps Transmit mode store and forward System exchange bandwidth 7 8G MAC address table 8K Memory 1M Interface Fast Ethernet Port 10Base T 100Base TX auto speed control Half full duplex and MDI MDI X auto detect Gigabit Combo port 1000Base X SFP slot or 10...

Reviews: