![3onedata IPS7110-2GC-4POE Series User Manual Download Page 50](http://html.mh-extra.com/html/3onedata/ips7110-2gc-4poe-series/ips7110-2gc-4poe-series_user-manual_444480050.webp)
CLI user manual
44
www.3onedata.com
For example, the maximum power of the configuration port 2 is 15W.
Switch(POE)#
Port_maxpower 15w 2
[OK]
For example, the priority for configuring port 5 is high.
Switch(POE)#
Priority high 5
[OK]
For example: setting the value of the total power of POE is 120W
Switch(POE)#
MAX_Power 120
[OK]
16.4 View port POE status information
Operating
Command
Description
View port POE status
information
Show poe_state
<port>
<port>:1-4
For example: view the status information of the PoE port 2.
Switch(POE)#
Show poe_state 2
Status : Disconnect
Class : 0
Current : 0.00
Current : 0.00
Current : 0.00
MAX Power: 30 W
Priority : High
enable : Disabled
Chapter 17 LLDP Setting
17.1 Enter LLDP settings view
Operating
Command
Description
Enter LLDP settings view
LLDP
Execute in system view
Switch#
LLDP
Switch(Lldp)#
?
List --List commands of current menu