3onedata IPS215-4POE User Manual Download Page 3

- 3 - 

100Base-FX full-duplex SM or MM port, SC/ST/FC  type .The 
fiber port must be used in pair, TX (transmit) port connect remote 
switch’s RX(receive) port; RX(receive) port connect remote 
switch’s TX(transmit) port. 

The optical fiber connection supports the line to instruct 

enhance the reliability of network effectively. 

Suppose

: If you make your own cable, we suggest labeling 

the two sides of the same line with the same letter (A-to-A and 
B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 

 

LED Indicator

 

LED indictor light on the front panel of product, the function of 
each LED is described in the table as below. 

System indication LED 

LED 

State 

Description 

PWR 

ON 

Power is being supplied to 
power input PWR input 

OFF 

Power is 

not

  being supplied to 

power input PWR input 

RUN 

ON/OFF 

System is not running well 

Blinking 

System is running well 

Link/ACT 

(1~5) 

ON 

Port connection is active 

OFF 

Port connection is not active 

Blinking 

Data transmitted 

POE 

(1~4) 

ON 

The PoE device is connected by 
IEEE802.3af/at standard 

OFF 

No PoE power output or no PoE 
connected PoE devices 

Installation

 

Before installation, confirm that the work environment meet the 
installation require, including the power needs and abundant 
space. Whether it is close to the connection equipment and other 
equipments are prepared or not.   
1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 
3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

4. Power: 45~55VDC power input 
5. Environment: working temperature: -40

75

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

DIN Rail Installation 

In order to use in industrial environments expediently, the product 
adopt 35mm DIN-Rail installation, the installation steps as below: 

1.

 

Examine the DIN-Rail attachment 

2.

 

Examine  DIN Rail whether be firm and the position is 
suitability or not. 

3.

 

Insert the top of the DIN-Rail into the slot just below the 
stiff metal spring. 

4.

 

The DIN-Rail attachment unit will snap into place as shown 
below. 

 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.

 

It is needed to check whether the type, quantity and 
specification of cable match the requirement before cable 
laying; 

2.

 

It is needed to check the cable is damaged or not, factory 
records and quality assurance booklet before cable laying; 

3.

 

The required cable specification, quantity, direction and 
laying position need to match construction requirements, and 
cable length depends on actual position; 

4.

 

All the cable cannot have break-down and terminal in the 
middle; 

5.

 

Cables should be straight in the hallways and turning; 

6.

 

Cable should be straight in the groove, and cannot beyond the 
groove in case of holding back the inlet and outlet holes. 
Cables should be banded and fixed when they are out of the 
groove; 

7.

 

User cable should be separated from the power lines. Cables, 
power lines and grounding lines cannot be overlapped and 
mixed when they are in the same groove road. When cable is 
too long, it cannot hold down other cable, but structure in the 
middle of alignment rack; 

8.

 

Pigtail cannot be tied and swerved as less as possible. 
Swerving radius cannot be too small (small swerving causes 
terrible loss of link). Its banding should be moderate, not too 
tight, and should be separated from other cables; 

9.

 

It should have corresponding simple signal at both sides of the 
cable for maintaining. 

Specification

 

Technology 

Standard: Support IEEE802.3, IEEE802.3u, IEEE802.3x, 

IEEE802.3af/at 

Exchange attribute 

100M forward speed: 148810pps 

Summary of Contents for IPS215-4POE

Page 1: ...tal case power supply input 48VDC The switch support IEEE802 3 IEEE802 3u with 10 100M full half duplex and MDI MDI X auto sensing providing reliable and economic solution for your industrial Ethernet network Packing list The industrial PoE switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Indu...

Page 2: ...LAN function that port 5 with port 1 4 can communication but between ports 1 to port 4 cannot communication 4 is keeping for future function Please power off and power on when you change the status of DIP switch Communication connector 10 100BaseT X Ethernet port The pinout define of RJ45 port display as below connect by UTP or STP The connect distance is no more than 100m 100Mbps is used 120Ωof U...

Page 3: ...order to use in industrial environments expediently the product adopt 35mm DIN Rail installation the installation steps as below 1 Examine the DIN Rail attachment 2 Examine DIN Rail whether be firm and the position is suitability or not 3 Insert the top of the DIN Rail into the slot just below the stiff metal spring 4 The DIN Rail attachment unit will snap into place as shown below Wiring Requirem...

Page 4: ...of input 3 bits terminal block IPS215 4POE Un load consumption 2 69W 48VDC Full load consumption 74 06W 48VDC IPS215 F 4POE Un load consumption 2 26W 48VDC Full load consumption 73 96W 48VDC Single PoE port maximum consumption 30W 48VDC The power supports reverse polarity protection Working environment Working temperature 40 75 Storage temperature 40 85 Relative Humidity 5 95 no condensation Mecha...

Reviews: