Step 1
Check if the DIN-Rail mounting kit is installed firmly.
Step 2
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【
Disassembling DIN-Rail
】
Step 1
Device power off.
Step 2
After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, then shift out the
bottom of DIN-Rail, disassembling ends.
Note before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【
Power Supply Connection
】
DC power supply
This device provides 3-pin 7.62mm pitch terminal blocks. This
power supply supports anti-reverse connection.
Power supply range: 48VDC (44~55VDC).
【
DIP Switch Setting
】
Provide 4-bits DIP switch for function setting,
where "ON" is enable valid terminal.
The definitions of DIP switch are as follows:
No.
Definition
Operation
1
Flow control
Set the switch to ON
2
Jumbo frame
Set the switch to ON
3
LFP alarm
Set the switch to ON
4
Reserved
-
【
Checking LED Indicator
】
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table as
below:
LED
Status
Description
PWR
ON
PWR is connected and running
normally
OFF
PWR is disconnected and running
abnormally
RUN
ON/OFF
Device runs abnormally
Blinking
Device runs normally
PoE
ON
POE port is powering other devices
OFF
POE port is not powering other devices
1
ON
Copper port has established valid
connection
Blinking
Copper port is in an active network
status
OFF
Copper port hasn
’
t established valid
connection
2
ON
Fiber port has established valid
connection
Blinking
Fiber port is in an active network status
OFF
Fiber port hasn
’
t established valid
connection
LFP
ON
Fiber/copper port is not connected or
connected abnormally
OFF
Fiber/copper port is connected
normally
【
Specification
】
Panel
100M copper port
10Base-T/100Base-TX
self-adaption
100M fiber port
100Base-FX, optional SFP or
SC/ST/FC interface
PoE
Maximum power of PoE port:
30W
PoE power supply pin: V+, V+,
V-, V- correspond to 1, 2, 3, 6
Indicator
Power supply indicator, remote
alarm
indicator,
fiber
port
connection
status
indicator,
copper port connection status
indicator, running indicator
S
witch property
100M forwarding speed
148810pps
Buffer size
1K
MAC address
2K
Power supply
Input power supply
DC power supply 48VDC
Support anti-reverse protection
Access terminal
3-pin 7.62mm pitch terminal
blocks
Power consumption
Model I
No-load: 1.63W@48VDC
Full-load: 18.39W@48VDC
Model Il
No-load: 1.97W@48VDC
Full-load: 18.62W@48VDC
Operating
environment
Operating temperature
-40~75
℃