3onedata IPMC101 Series Quick Installation Manual Download Page 2

 

Step 1 

Check if the DIN-Rail mounting kit is installed firmly. 

Step 2 

Insert the bottom of DIN-Rail mounting kit (one side 

with  spring  support)  into  DIN-Rail,  and  then  insert 

the top into DIN-Rail. 

Tips: 

Insert a little to the bottom, lift upward and then insert 

to the top. 

Step 3 

Check and confirm the product is firmly installed on 

DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

 

Step 1 

Device power off. 

Step 2 

After lift the device upward slightly, first shift out the 

top  of  DIN-Rail  mounting  kit,  then  shift  out  the 

bottom of DIN-Rail, disassembling ends. 

Note before powering on:

 

 

Power ON operation: first connect power line to the 

connection terminal of device power supply, then power 

on. 

 

Power OFF operation: first unpin the power plug, then 

remove the power line, please note the operation order 

above.   

Power Supply Connection

 

 

DC power supply 

This device provides 3-pin 7.62mm pitch terminal blocks. This 

power supply supports anti-reverse connection. 

Power supply range: 48VDC (44~55VDC). 

 

DIP Switch Setting

 

Provide 4-bits DIP switch for function setting, 

where "ON" is enable valid terminal.   

The definitions of DIP switch are as follows: 

No. 

Definition 

Operation 

Flow control 

Set the switch to ON   

Jumbo frame 

Set the switch to ON 

LFP alarm 

Set the switch to ON 

Reserved 

Checking LED Indicator

 

The  device  provides  LED  indicators  to  monitor  its  operating 

status,  which  has  simplified  the  overall  troubleshooting 

process. The function of each LED is described in the table as 

below:   

LED 

Status

 

Description

 

PWR 

ON 

PWR is connected and running 

normally 

OFF 

PWR is disconnected and running 

abnormally 

RUN 

ON/OFF 

Device runs abnormally 

Blinking 

Device runs normally 

PoE 

ON 

POE port is powering other devices 

OFF 

POE port is not powering other devices 

ON 

Copper port has established valid 

connection 

Blinking 

Copper port is in an active network 

status 

OFF 

Copper port hasn

t established valid 

connection 

ON 

Fiber port has established valid 

connection 

Blinking 

Fiber port is in an active network status 

OFF 

Fiber port hasn

t established valid 

connection 

LFP 

ON 

Fiber/copper port is not connected or 

connected abnormally 

OFF 

Fiber/copper port is connected 

normally

 

Specification

】 

Panel 

 

100M copper port 

10Base-T/100Base-TX 

self-adaption 

100M fiber port 

100Base-FX,  optional  SFP  or 

SC/ST/FC interface

 

PoE 

Maximum  power  of  PoE  port: 

30W 

PoE  power  supply  pin:  V+,  V+, 

V-, V- correspond to 1, 2, 3, 6 

Indicator 

Power  supply  indicator,  remote 

alarm 

indicator, 

fiber 

port 

connection 

status 

indicator, 

copper  port  connection  status 

indicator, running indicator 

S

witch property

 

 

100M forwarding speed

 

148810pps

 

Buffer size 

1K

 

MAC address 

2K

 

Power supply

 

 

Input power supply

 

DC power supply 48VDC 

Support anti-reverse protection

 

Access terminal 

3-pin  7.62mm  pitch  terminal 

blocks 

Power consumption 

 

Model I 

No-load: 1.63W@48VDC 

Full-load: 18.39W@48VDC 

Model Il 

No-load: 1.97W@48VDC 

Full-load: 18.62W@48VDC 

Operating 

environment 

 

Operating temperature 

-40~75

 

Reviews: