3onedata IES7120G Series Quick Installation Manual Download Page 2

 

Check if the DIN-Rail mounting kit is installed 

Step 1

firmly. 

 

Insert the bottom of DIN-Rail mounting kit (one 

Step 2

side with spring support) into DIN-Rail, and then 
insert the top into DIN-Rail. 

Tips: 
Insert a little to the bottom, lift upward and then insert 
to the top. 

 

Check and confirm the product is firmly installed on 

Step 3

DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

 

 

Power off the device. 

Step 1

 

After lift the device upward slightly, first shift out the 

Step 2

top of DIN-Rail mounting kit, then shift out the 
bottom of DIN-Rail, disassembling ends. 

Attention before powering on: 

 

Power ON operation: first connect power line to the 
connection terminal of device power supply, then 
power on. 

 

Power OFF operation: first unpin the power plug, then 
remove the power line, please note the operation order 
above.   

Power Supply Connection

 

 

DC power supply 

This series provide 4-pin power supply 
input terminal blocks and two 
independent DC power supply systems of 
PWR1 and PWR2. The power supply 
supports nonpolarity and anti-reverse 

connection; it can normally operate after reverse connection. 
Power supply range: 12

48VDC 

Relay Connection

 

Relay terminals are a pair of normally open 
contacts in the alarm relay of the device. They 
are open circuit in normal non alarm state, 

closed when any alarm message  occurs.  For example: it's 

closed  and sends  out alarm when power off. This series 
support 1 channel relay alarm information output, and  DC 
power alarm information or network abnormal alarm output. It 
can be connected to alarm indicator, alarm buzzer, or other 
switching value collecting devices for timely warning operator 
when alarm information occurs. 

DIP Switch Setting

 

This series provide 4-pin DIP switch for function 
settings, among which "ON" is enable valid 
terminal. Please power off and power on after 
changing the status of DIP switch. DIP switch 

definitions as follows: 

1.  Restart 

2.  Restore factory defaults 

3.  Reserved 

4.  Reserved 

Console Port Connection

 

This series  provide  1 channel procedure debugging port 
based on serial port, and can manage the CLI command line 
of the  device  after connected to PC. The interface adopts 
RJ45 port, the RJ45 pins definition as follows: 

Pin No. 

Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

The function of each LED is described in the table as below:   

LED 

Status  Description 

P1 

ON 

PWR1 is connected and running 
normally 

OFF 

PWR1 is disconnected and running 
abnormally. 

P2 

ON 

PWR2 is connected and running 
normally 

OFF 

PWR2 is disconnected and running 
abnormally 

ALM 

ON 

Power supply and port link alarm 

OFF 

Power supply and port link without 
alarm 

RUN 

ON 

The device is powering on or the 
device is abnormal. 

OFF 

The device is powered off or the 
device is abnormal. 

Blinking 

Blink once per second, the device 
is running normally. 

Link/ACT 
(1-16/20) 

ON 

Ethernet port connection is active. 

Blinking  Data transmitted 
OFF 

Ethernet port connection is inactive. 

Logging in to WEB Interface

 

This device supports WEB management and configuration. 
Computer can access the device via Ethernet interface. The 
way of logging in to device’s configuration interface via IE 
browser is shown as below: 

 

Configure the IP addresses of computer and the 

Step 1

device to the same network segment, and the 
network between them can be mutually accessed. 

 

Enter device’s IP address in the address bar of the 

Step 2

computer browser. 

 

 

Enter device’s username and password in the login 

Step 3

window as shown below. 

 

 

Click “OK” button to login to the WEB interface of 

Step 4

the device. 

Note: 