3onedata IES7110-2GS Series User Manual Download Page 2

- 2 - 

 

1. DIP switches for default factory 

2. Console port 

3. 2-pin terminal block for relay output   

4. Ground screw 

5. Power input terminal block 

6. Screw holes for Wall Mounting Kit   

7. DIN-Rail mounting kit   

8. Power indicator 

9. System running LED   

10. Relay alarm LED 

11. Link/ACT LEDs   

12. Gigabit SFP port 

13. 10Base-T /100Base-TX Ethernet port 

14. 100Base-FX fiber port 

Power supply input

 

DC Series Switch: 

 

The product top panel provided 4 bit power supply input terminal 

block,  support  DC  input.  DC  power  supply  input  supported 

redundancy  function,  provided  PWR1  and  PWR2  power  input, 

can  use  for  single,  and  can  connect  2  separately  power  supply 

system,  use  1 pair terminal  block  connect  the  device  at  the  same 

time.  If  one  of  the  power  systems  broke,  the  device  can  work 

un-interruptible. 

Built-in 

overcorrect 

protection, 

Reverse 

connection  protection.  Voltage  input  range  is  12

48VDC

terminal block defined as: V1-

V1+

V2-

V2+

AC Series Switch: 

 

The  Industrial  Ethernet  switches  have  singe  power  and 

redundancy power two kinds of power input. The singe power AC 

series  top  panel  provides  3  bit  terminal  block  for 

100~240VAC/DC power entered (L/+, FG, N/-) 

Important notice: 

1.

 

Power ON operation: first of all, insert power cable’s terminal 

block into device’s power port, then insert power supply plug into 

power source 

2.

 

Power  OFF  operation:  First  off  all,  unpin  power  plug,  then 

strike the terminal block, please take care of operation sequence. 

Dimension

 

The  series  of  products  are  the  same  size,  and  the  number  of  the 

Ethernet interface is different. Unit (mm)

 

 

DIP Switch

 

 

Top  panel  provided  4  bits  DIP  switch  to  do  function  configure

ON to enable effective

,1 and 4 keep for future function. 2 is 

recovery  default  factory.  3  is  for  upgrade.  Please  power  off  and 

power on when you change the status of DIP switch. 

Relay connection

 

 

Relay access terminals in the top panel of the device. Between the 

two  terminal  relay,  as  an  open  circuit  state  in  normal  non  alarm 

state, when there is any alarm information to the closed state. The 

two terminal block connector are used to detect both power failure 

and port failure. The

 

two wires attached to the Fault contacts form 

an open circuit when the device has lost power supply from one of 

the DC power inputs or one of the ports is failure. (Note: The AC 

power switch does not support power alarm.) 

Console port

 

This  series  product  provided  1pcs  procedure  test  port  based  in 

serial  port.  It  adopts  RJ45  interface,  located  in  top  panel,  can 

configure related command through RJ45 to DB9 female cable. 

 

Communication connector

 

10/100BaseT(X) Ethernet port 

The pinout define of RJ45 port display as below, connect by UTP 

or STP. The connect distance is no more than 100m. 100Mbps is 

Summary of Contents for IES7110-2GS Series

Page 1: ...ogy for fault of rapid redundant network the recovery time 20ms Packing list The industrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch 1 Documentation and software CD 1 User manual 1 DIN Rail mounting kit 1 Warranty card 1 Feature High performance netw...

Page 2: ...port then insert power supply plug into power source 2 Power OFF operation First off all unpin power plug then strike the terminal block please take care of operation sequence Dimension The series of products are the same size and the number of the Ethernet interface is different Unit mm DIP Switch Top panel provided 4 bits DIP switch to do function configure ON to enable effective 1 and 4 keep fo...

Page 3: ...ferent transfer distance Fiber interface must use for pair TX port is transmit side must connect to RX receive side The fiber interface support loss line indicator Suppose If you make your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B shown as below or A1 to A2 and B1 to B2 LED Indicator LED indictor light on the front panel of product the func...

Page 4: ...ignment rack 8 Pigtail cannot be tied and swerved as less as possible Swerving radius cannot be too small small swerving causes terrible loss of link Its banding should be moderate not too tight and should be separated from other cables 9 It should have corresponding simple signal at both sides of the cable for maintaining Specification Technology Standard Support IEEE802 3 IEEE802 3u IEEE802 3x I...

Page 5: ...hell Installation DIN Rail mounting Weight 720g Size W H D 110mm 138mm 53mm Industry Standard EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level 4 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 4 EN61000 4 5 Surge Level 4 EN61000 4 6 CS Level 3 EN61000 4 8 Level 5 Shock IEC 60068 2 27 Free fall IEC 60068 2 32 Vibration IEC 60068 2 6 Certification CE FCC RoHS UL508 Pending Warranty 5 yea...