Check if the DIN-Rail mounting kit is installed firmly. 

 

Clip the upper part of the DIN-Rail mounting kit, i.e. 
the fixed side, into the DIN rail. 

 

Press the lower side of the device and insert the 
lower part of DIN-Rail mounting kit (the side with 
spring support) into DIN-Rail. 

Tips: 
The DIN-Rail spring support is a metal sheet that can 
move up and down, and there will be a sound after it is 
clamped in. 

 

Check and confirm the product is firmly installed on 
DIN rail, then mounting ends. 

Disassembling DIN-Rail

 

 

 

Power off device. 

 

Use a slot type screwdriver or other tools to move 
the DIN rail spring support downward; At the same 
time, move the lower side of the device outward 
and move out the lower part of the DIN rail 
mounting kit. 

 

Lift the device upward slightly, move out the upper 
part of DIN-Rail mounting kit. Disassembling ends. 

Notice before power on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
then plug the power supply plug contact and power on. 

 

Power OFF operation: First, remove the power plug, 
then remove the wiring section of terminal block. Please 
pay attention to the above operation sequence. 

Power Supply Connection

 

The device provides 6-pin 5.08mm pitch 
power supply terminal blocks and power 
supply occupies the left 4 pins. It supports 
two independent DC power supply 
systems, P1 and P2. The series of device 

supports redundant power supply, two power supply can work 
at the same time. The device will still run non-stop when one 
power supply fails. Power supply supports anti-reverse 
connection, which protect the device from damage but the 
device cannot be powered on. The definitions of power pin are 
shown in the figure above, and the power input range is 
50~55VDC. 

Note: 

 

If the POE port uses IEEE802.3bt PoE++ standard, the 
device power input range must be 50~55VDC; 

 

If the POE port uses IEEE802.3af/at PoE/PoE+ standard, 
the device power input range is 48~55VDC. 

Relay Connection

 

This device provides 6-pin 5.08mm pitch 
terminal blocks, relay occupies the right 2 
pins. Relay terminals are a set of normally 
open contacts of the device alarm relay. 
They are open circuit in the state of 

normal non alarm, closed when any alarm information occurs. 
For example, they are closed when powered off, and send out 
alarm. The switch supports 1 relay alarm information output 
that can output power supply alarm or network abnormality 

alarm. It can be connected to alarm light or alarm buzzer or 
other switching value collecting devices, which can timely 
inform operators when the alarm occurs.

 

DIP Switch Settings

 

The device provides 4-pin DIP switch for function 
setting, in which “ON” is the enabled end. The 
definitions of DIP switch are as follows: 

 

DIP  Definition 

Operation 

Restore Factory 
Settings 

Set the DIP switch to ON, the 
device will root automatically 
and restore to factory settings, 
then turn off the DIP switch. 

2-4  Reserved 

 

I/O Po

rt Connection

 

This device provides 8-pin 3.81mm 
pitch terminal blocks and 2 DI and 2 
DO. This device can detect and 

send I/O input status to management software, operators can 
set the conditions of alarm status via management software. 
When the I/O input status meets the set alarm conditions, the 
I/O output alarm would be triggered. The pin definitions of I/ O 
port are shown as follows:

 

I/O Port 

PIN 

Definition 

DI digital signal input 1 

DI1+, DI1- 

I/O signal 
input 

DI digital signal input 2 

DI2+, DI2- 

DO digital signal output 1  DO1+, DO1- 

I/O relay 
output 

DO digital signal output 2  DO2+, DO2- 

Console Port Connection

 

The device provides 1 program debugging port 
based on RS-232 serial port which can conduct 
device CLI command management after 

connecting to PC. The interface adopts RJ45 port, the RJ45 
pin definition as follows: 

Pin No. 

Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

Summary of Contents for IES6300-8GHP2GS2HS-2P48-360W

Page 1: ...ight view 1 Input terminal blocks for Power Supply P1 2 Input terminal blocks for Power Supply P2 3 Relay alarm output terminal block 4 DIP switch 5 Console port 6 Grounding screw 7 DIN Rail mounting kit 8 Power supply indicator P1 P2 9 Running indicator RUN 10 Alarm indicator ALM 11 I O input and output interfaces DI1 DI2 DO1 DO2 12 I O indicator DI1 DI2 DO1 DO2 13 100 1000Base X SFP slot G11 G12...

Page 2: ...d the device power input range must be 50 55VDC If the POE port uses IEEE802 3af at PoE PoE standard the device power input range is 48 55VDC Relay Connection This device provides 6 pin 5 08mm pitch terminal blocks relay occupies the right 2 pins Relay terminals are a set of normally open contacts of the device alarm relay They are open circuit in the state of normal non alarm closed when any alar...

Page 3: ...ess the device s Web interface Note The default IP address of the device is 192 168 1 254 The default user name and password of the device are admin When logging in to the device for the first time the system will prompt to change the initial password of the default user The length of the new password string must be greater than or equal to 8 and be composed of two or more kinds of uppercase lette...

Page 4: ...vercurrent protection Access terminal block 6 pin 5 08mm pitch terminal blocks power supply occupies 4 pins Power Consumption No load 5 5W 50VDC Full load 380W 50VDC with 360W PoE Load Working Environment Working temperature 40 75 Storage temperature 40 85 Working humidity 5 95 no condensation Protection grade IP40 metal shell ...

Reviews: