background image

please don't directly contact to avoid scalding. 

DIN-Rail Mounting

 

For convenient usage in industrial environments, the product 

adopts 35mm DIN-Rail mounting, mounting steps as below: 

 

 

Check  whether  the  DIN-Rail  mounting  kit  that 

Step 1

comes with the device is installed firmly. 

 

Insert the bottom of DIN-Rail mounting kit (one side 

Step 2

with  spring  support)  into  DIN-Rail,  and  then  insert 

the top into DIN-Rail. 

Tips: 

Insert a little to the bottom, lift upward and then insert 

to the top. 

 

Check and confirm the product is firmly installed on 

Step 3

DIN-Rail, and then mounting ends. 

Disassembling DIN-Rail

 

 

Power off the device. 

Step 1

 

After lift the device upward slightly, first shift out the 

Step 2

top of DIN-Rail mounting kit, and then shift out the 

bottom of DIN-Rail, disassembling ends. 

Attention before powering on: 

 

Power ON operation: first connect power line to the 

connection terminal of device power supply, and then 

power on. 

 

Power OFF operation: first unpin the power plug, and 

then remove the power line, please note the operation 

order above. 

Power Supply Connection

 

 

DC power supply 

The product provides 4 pins power supply 

input 

terminal 

blocks 

and 

two 

independent DC power supply systems of 

PWR1  and  PWR2.  The  power  supply 

supports  nonpolarity  and  anti-reverse 

connection. It can normally operate after reverse connection. 

Power supply range: 12

48VDC 

Serial Port Connection

 

 

RS-232 serial port 

The RS-232 serial port of this series 

device adopts DB9 male connector, and 

supports serial server function. The pin 

definition as shown in the follow table: 

PIN 

RS-232 

DCD 

RXD 

TXD 

DTR 

GND 

PIN 

 

RS-232 

DSR 

RTS 

CTS 

RI 

 

 

RS-485/422 serial port 

This series devices provide 5.08mm 

pitch 5-pin industrial terminal block and 

support RS-485/RS-422 serial port 

connection. The pin definitions as shown 

in the follow table: 

PIN 

RS-485 

D+ 

D- 

GND 

— 

— 

RS-422 

T+ 

T- 

GND 

R+ 

R- 

Relay Connection

 

Relay terminal blocks are a pair of normally open contacts in 

the  alarm  relay  of  the  device.  They  are  open 

circuit  in  the  status  of  normal  no  alarm,  and 

closed  when  any  warning  message  occurs.  For 

example: they are closed and send out alarm when power off. 

The  product  supports  1  relay  warning  message  output,  and 

warning messages output of the DC power supply or network 

abnormal alarm output. It can be connected to alarm indicator, 

alarm  buzzer,  or  other  switching  value  collecting  devices  for 

timely  warning  operating  staffs  when  the  warning  message 

occurs. 

DIP Switch Settings

 

The  product  provides  4  pins  DIP  switch  for 

function settings, where "ON" is the enable valid 

terminal. 

DIP switch definitions as follows: 

DIP 

Definition 

Operation 

Reserved 

 

Reserved 

 

AT mode 

Set the DIP switch to ON, 

user can enter AT command 

mode via serial port 

Restore factory 

defaults 

Set the DIP switch to ON, 

power on the device again, 

and turn off the DIP switch. 

Checking LED Indicator

 

This  device  provides  LED  indicators  to  monitor  the  working 

conditions  of  the  device,  which  has  simplified  the 

troubleshooting process comprehensively. The detailed status 

of each LED is described in the table as below:   

LED 

Status 

Description 

PWR 

(1-2) 

ON 

PWR is connected and running 

normally 

OFF 

PWR is disconnected and running 

abnormally. 

RUN 

ON 

The device is powering on or 

abnormal. 

OFF 

The device is powered off or 

abnormal. 

Blinking 

Blink once per second, the device is 

running well. 

Link/A

ct 

(1-5) 

ON 

Ethernet port has established valid 

network connection. 

Blinking 

Ethernet port is in an active network 

status. 