3onedata IES5328 Series Quick Installation Manual Download Page 2

supply specification to avoid over-voltage damaging 
the device. 

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

Rack-Mounting

 

This product adopts rack-mounting, mounting steps as 
below: 
Step 1 

Select the device mounting location to ensure 

enough size. 

Step 2 

Adopt 4 bolts to install the mounting lugs in the 

device position as figure below. 

 

Step 3 

Place the device in the rack; adopt 4 bolts to fix 

two sides mounting lugs in the rack. 

 

Step 4 

Check and confirm the product is mounted firmly 

on the rack, mounting ends. 

Disassembling Device

 

Step 1 

Device power off. 

Step 2 

Adopt screw driver to loosen the 4 bolts fixed on 

the mounting lugs in the rack. 

Step 3 

Shift out the device from rack, disassembling 

ends. 

Notice before power on: 

 

Power ON operation: First insert the power supply 

terminal block into the device power supply interface, 
then plug the power supply plug contact and power 
on. 

 

Power switch “—” means power ON, “O” means 
power OFF. 

 

Power OFF operation: First, put the powers switch to 
the "O" side and then disconnect the power supply. 
Finally disconnect the connector between the device 
and the power cord. Please notice the operation order 
above. 

 

Please be aware of the power input range supported 
by the device before powering on. Use the 
recommended voltage of the device to avoid device 
damage. 

Power Supply Connection

 

 

AC power supply 

The Model I of this device provides 2 AC power 
supply access ports which come with a switch.

 

Voltage range: 220VAC (100~240VAC/DC) 

 

DC power supply 

Model II, III of this device provide 2 DC power supplies 
which are 5-pin 5.08mm pitch terminal blocks. The power 
supply occupies 3 pins on the left side and supports 
anti-reverse connection. 

  Power supply range of Model II: 48VDC (36~72VDC). 

  Power supply range of Model III: 24VDC (18~72VDC). 

Restore Default Settings

 

RESET is restoring default settings button. Device Restoring 
default settings steps as follows: press and hold the RESET 
button, power on the device again, wait for about 3~4 
seconds to restore the factory settings. 

Relay Connection

 

 

DC products 

Model II, III of this device support 2 
relay alarm information outputs which 
are 5-pin 5.08mm pitch terminal blocks. 

It occupies 2 pins on the right side and R+ and R- are relay 
alarm output parts. They are open circuit in normal non 
alarm state, closed when any alarm information occurs. The 
relay can externally connect to alarm lights or alarm buzzer 
or other switching value collecting device in order to timely 
notify operators when the alarm occurs. 

 

AC products 

Model I of this device support 2 relay 
alarm information outputs which are 
5-pin 5.08mm pitch terminal blocks. It 

occupies 2 pins on the right side and R+ and R- are relay 
alarm output parts. They are open circuit in normal non 
alarm state, closed when any alarm information occurs. The 
relay can externally connect to alarm lights or alarm buzzer 
or other switching value collecting device in order to timely 
notify operators when the alarm occurs.

 

Console Port Connection

 

The device provides 1 program debugging port based on 
RS-232 serial port which can conduct device CLI command 
management after connecting to PC. The interface adopts 
RJ45 port, the RJ45 pin definition as follows: 

Pin No. 

Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

The series products provide LED indicators to monitor the 
device working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 
table as below: 

LED 

Indicate 

Description 

P1 

ON 

PWR is connected and running 
normally 

OFF 

PWR is disconnected or running 
abnormally 

P2 

ON 

PWR is connected and running 
normally 

Reviews: