3onedata IES5024 Series Quick Installation Manual Download Page 2

 

Attention before mounting:

 

 

Don't  place  or  install  the  device  in  moist  area  or  near 

water,  keep  the  relative  humidity  of  the  device

 

surrounding between 5%~95% without condensation. 

 

Before  power  on,  first  confirm  the  supported  power 

supply specification to avoid over-voltage damaging the 

device. 

 

The  device  surface  temperature  is  high  after  running, 

please don't directly contact to avoid scalding. 

Installation of Rack-mounted Device

 

Select  the  device  installation  location  to  reserve  sufficient 

size. 

Step 1 

Adopt  screws  to  install  the  mounting  lugs  in  the 

device position as figure below. 

 

Step 2 

Place  the  device  in  the  rack,  adopt  4  screws  to 

install the mounting lugs on the left and right side in 

the rack. 

 

Step 3 

Check and confirm the product is firmly installed on 

the rack, then mounting ends. 

Rack-mounting Device Disassembling

 

Step 1 

Power off the device. 

Step 2 

Unscrew  the  fixing  screw  of  mounting  lug  on  the 

rack. 

Step 3 

Remove  the  device  from  the  rack,  disassembling 

ends. 

Power Supply Connection

 

This series of devices provide 5 pins 5.08mm pitch terminal 

blocks, power supply occupies 3 pins on the left.The power 

supply has nonpolarity and anti-reverse function, the device 

can be normally working after reverse connection. The pin 

definition of power supply as follows: 

Pin NO. 

Definition 

L/+ 

GND 

N/- 

 

Single power supply 

This series of products supports single power supply scheme, 

power 

supply 

value 

range 

is: 

100~240VAC/DC.

 

 

 

Dual power supply 

This  series  of  products  support  dual 

power  supply  scheme  and  provide  P1 

and  P2  independent  power  supply 

systems. When one of the power supply 

system  fails,  the  device  can  operate 

uninterruptedly and normally, which has 

improved  the  reliability  of  network  operation.  Power  supply 

value range is: 100~240VAC/DC.

 

 

Notes:

 

 

Power  ON  operation:  First  insert  the  power  supply 

terminal  block  into  the  device  power  supply  interface, 

and then plug the power supply plug contact and power 

on. 

 

Power  OFF  operation:  First  unpin  the  power  plug,  and 

then  remove  the  wiring  part  of  terminal  block,  please 

pay attention to the operation order above. 

Relay Connection

 

This  series  of  devices  provide  5  pins  5.08mm  pitch  terminal 

blocks;  power  supply  occupies  3  pins  on  the  left.  Relay 

terminals  are  a  pair  of  normally  closed  contacts  in  device 

alarm relay. They are open circuit in normal non alarm state, 

closed  when  power  off.  This  series  of single and dual  power 

supply  products  respectively  support  1  or  2  channels  relay 

alarm output and disconnection alarm of power supply or port. 

The device can be connected to alarm indicator, alarm buzzer, 

or other switching value collecting device; it can timely inform 

operator  when  alarm  occurs.  The  pin  definition  of  relay  as 

follows: 

Pin NO. 

Definition 

R+ 

R- 

Console Port Connection

 

The  device  provides  1  program  debugging  port  based  on 

RS-232 serial port; it can manage the device CLI commands 

after being connected to PC. The interface adopts RJ45 port. 

Summary of Contents for IES5024 Series

Page 1: ...ts are 24 port 100M layer 2 rack mounted managed industrial Ethernet switches Models include Model I IES5024 24 100M copper ports Model II IES5024 2F 22 100M copper ports 2 100M fiber ports Model III IES5024 4F 20 100M copper ports 4 100M fiber ports Model IV IES5024 8F 16 100M copper ports 8 100M fiber ports Model V IES5024 12F 12 100M copper ports 12 100M fiber ports Model VI IES5024 16F 8 100M ...

Page 2: ...orts single power supply scheme power supply value range is 100 240VAC DC Dual power supply This series of products support dual power supply scheme and provide P1 and P2 independent power supply systems When one of the power supply system fails the device can operate uninterruptedly and normally which has improved the reliability of network operation Power supply value range is 100 240VAC DC Note...

Page 3: ...n below Step 4 Click OK button to login to the WEB interface of the device Note The default IP address of the device is 192 168 1 254 The default username and password of the device is admin If the username or password is lost user can restore it to factory settings via device DIP switch or management software all modified configurations will be cleared after restoring to factory settings so pleas...

Page 4: ...IES5024 16F No load 17 8W 220VAC Full load 20 5W 220VAC Environmental Limits Working temperature 40 75 Storage temperature 40 85 Working humidity 5 95 no condensation Protection grade IP30 metal shell ...

Reviews: