- 2 - 

Dimension

 

The series of products are the same size, and the number of the 

Ethernet interface is different. Unit (mm)

 

 

Power supply input

 

 

The  switch  have redundant power input, provides one terminal 

block (4 bits) for PWR1 and PWR2 input. The redundant power 

can be used single and used two self-governed power to supply to 

the system, PWR1 and PWR2 input at the same time, when 

neither of  these two power fails, the other power  acts as a 

backup, and  automatically supplies power needs,  ensure running   

Ethernet reassuring. Voltage input range is 12

48VDC (terminal 

block defined as: V1-

V1+

V2-

V2+). 

DIP Switch

 

 

Provide 10 bits switch for function setting. 1

8 alarm enable 

switch setting, ON show enable. 9 show PWR2 alarm setting, 10 

show PWR 1 alarm setting, ON show alarm state. 

Relay connection

 

 

The  relay  consists of the two middle contacts of the terminal 

block on the switch’s top panel. The two terminal block connector 

are used to detect both power faults and port faults. The

 

two wires 

attached to the Fault contacts form an open circuit when: 

(1) The switch have lost power from one of the DC power inputs. 

(2) One of the ports for which the corresponding Port alarm DIP 

Switch is set to ON is not properly connected. 

If neither of these two conditions occurs, the alarm circuit will be 

closed. 

Communication connector

 

10/100BaseT(X) Ethernet port 

The pinout define of RJ45 port display as below, connect by UTP 

or STP. The connect distance is no more than 100m. 100Mbps is 

used 120

Ω

of UTP 5, 10Mbps is used 120

Ω

of UTP 3 ,4, 5. 

 

RJ 45 port support automatic MDI/MDI-X operation. can 

connect the PC, Server, Converter and HUB .Pin 1,2,3,6 

Corresponding  connection  in  MDI.  1→3,  2→6,  3→1,  6→2  are 

used as cross wiring in the MDI-X port of Converter and HUB. 

10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin 

in the table as below. 

NO. 

MDI signal 

MDI-X signal 

TX+ 

RX+ 

TX- 

RX- 

RX+ 

TX+ 

RX- 

TX- 

4, 5, 7, 8 

 

 

Note: “TX

±

” Transmit Data

±

, “RX

±

” Receive Data

±

, “

” Not use.

 

10/100Base-T(X) MDI (straight-through cable) 

 

10/100Base-T(X) MDI-X (Cross over cable) 

 

MDI/MDI-X auto connection makes switch easy to use for 

customers without considering the type of network cable. 

100Base-FX Fiber port   

100Base-FX full-duplex SM or MM port, SC/ST/FC  type .The 

fiber port must be used in pair, TX (transmit) port connect remote 

switch’s RX(receive) port; RX(receive) port connect remote 

switch’s TX(transmit) port. 

The optical fiber connection supports the line to instruct 

enhance the reliability of network effectively. 

Suppose

:  If you make your own cable, we suggest  labeling 

the two sides of the same line with the same letter (A-to-A and 

B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 

1

8

Summary of Contents for IES308-1F-P

Page 1: ...witch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch ⅹ 1 User manual ⅹ 1 DIN Rail mounting kit ⅹ 1 Warranty card ⅹ 1 Feature Support IEEE802 3 IEEE802 3u IEEE 802 3x Ethernet port support Plug and play 10 100M F H duplex MDI MDI X auto negotiation Broadcast storm protecti...

Page 2: ...neither of these two conditions occurs the alarm circuit will be closed Communication connector 10 100BaseT X Ethernet port The pinout define of RJ45 port display as below connect by UTP or STP The connect distance is no more than 100m 100Mbps is used 120Ωof UTP 5 10Mbps is used 120Ωof UTP 3 4 5 RJ 45 port support automatic MDI MDI X operation can connect the PC Server Converter and HUB Pin 1 2 3 ...

Page 3: ... Wiring Requirements Cable laying need to meet the following requirements 1 It is needed to check whether the type quantity and specification of cable match the requirement before cable laying 2 It is needed to check the cable is damaged or not factory records and quality assurance booklet before cable laying 3 The required cable specification quantity direction and laying position need to match c...

Page 4: ...on 2 2W 12VDC IES308 1F P 12 48VDC Unload consumption 1 7W 12VDC Full load consumption 3 1W 12VDC IES308 2F P 12 48VDC Unload consumption 3 6W 12VDC Full load consumption 4 3W 12VDC Working environment Working temperature 40 75 Storage temperature 40 85 Relative Humidity 5 95 no condensation Mechanical Structure Shell IP30 protect grade metal shell Installation DIN Rail Size W H D 53mm 136mm 105mm...

Reviews: