Status
Description
When powered on,
TX, RX at A2 end
connect to RX, TX at A1
side separately,
TX, RX at B2 end
connect to RX, TX at B1
side separately.
When powered off,
TX, RX at A1 side
connects to RX, TX at
B1 side
Bypass function
According to the specification of SFP optical module, the
usage of fiber port Bypass is as follows:
When SFP optical module is single-mode double-fiber, 1 set
of Bypass function is supported. Connection method is
shown below.
When SFP optical module is sing-mode single-fiber, 2 sets
of Bypass function are supported. The solid line and dotted
line each presents 1 set of Bypass connection method as
shown below:
When the switch is normally powered on and operating, it can
communicate with other devices normally. When it
’s powered
off, fiber port A and B can connect to each other without
interfering other devices
’ normal communication.
【
DIP Switch Setting
】
This device provides 4-bit DIP switch for function
setting. “ON” is enable valid port. Please power
off and power on after changing the status of DIP
switch.
The definitions of DIP switches are as follows:
1.restore factory setting
2.reserved
3.reserved
4.reserved
【
Console Port Connection
】
This device provides an application debugging port based on
RS232 serial port which could connect to PC for device
’s CLI
command management. It adopts RJ45 port, and its pin
definitions are as follows:
Pin
2
3
5
Definition
TXD
RXD
GND
【
Checking LED Indicator
】
The device provides LED indicators to monitor device
’s
operation
status
and
comprehensively
simplify
troubleshooting process. The detailed status of each LED is
described in the table as below:
LED
Status
Description
PWR1
ON
Power
supply
P1
is
connected normally
OFF
Power
supply
P1
is
disconnected
or
running
abnormally
PWR2
ON
Power
supply
P2
is
connected normally
OFF
Power
supply
P2
is
disconnected
or
running
abnormally
ALM
ON
Power supply or port link is
giving an alarm
OFF
Power supply or port link isn
’t
giving any alarm
RUN
ON
Device is powered on or
running abnormally
OFF
Device is powered off or
running abnormally
Blinking
Blinking 1 time/s, device
operates normally
Link/Act
(1
~
12)
ON
Ethernet port has established
an active network connection
Blinking
Ethernet port is in an active
network state
OFF
Ethernet
port
hasn
’t
established an active network
connection
PoE
(G1-G12)
(only
for
PoE
product)
ON
PoE port is powering other
devices normally
OFF
PoE port is not powering
other
devices
or
disconnected
【Specification】
Panel
Gigabit SFP
1000Base-SFP, SFP slot
Gigabit copper port
10/100/1000Base-T(X)
self-adaptive RJ45 port, full/half
self-adaption,
MDI/MDI-X
self-adaption