3onedata IES1028 Series Quick Installation Manual Download Page 2

9. 

Relay output terminal block 

10. 

Gigabit SFP slot 

11. 

Ethernet port connection indicator 

12. 

100M copper port 

13. 

100M fiber port 

Mounting Dimension

 

Unit: mm 

 

Attention before mounting:

 

 

Don't  place  or  install  the  device  in  moist  area  or  near 

water,  keep  the  relative  humidity  of  the  device

 

surrounding between 5%~95% without condensation. 

 

Before  power  on,  first  confirm  the  supported  power 

supply specification to avoid over-voltage damaging the 

device. 

 

The  device  surface  temperature  is  high  after  running, 

please don't directly contact to avoid scalding. 

Installation of Rack-mounted Device

 

Step 1 

Select  the  device  installation  location  to  reserve 

sufficient size. 

Step 2 

Adopt  screws  to  install  the  mounting  lugs  in  the 

device position as figure below. 

 

Step 3 

Place  the  device  in  the  rack,  adopt  4  screws  to 

install the mounting lugs on the left and right side in 

the rack. 

 

Step 4 

Check and confirm the product is firmly installed on 

the rack, then mounting ends. 

Rack-mounting Device Disassembling

 

Step 1 

Power off the device. 

Step 2 

Unscrew  the  fixing  screw  of  mounting  lug  on  the 

rack. 

Step 3 

Remove  the  device  from  the  rack,  disassembling 

ends. 

Power Supply Connection

 

This series of devices provide 5 pins 5.08mm pitch terminal 

blocks, power supply occupies 3 pins on the left.The power 

supply has nonpolarity and anti-reverse function, the device 

can be normally working after reverse connection. The pin 

definition of power supply as follows: 

Pin NO. 

Definition 

L/+ 

GND 

N/- 

 

Single power supply 

This  series  of  products  supports  single 

power  supply  scheme,  power  supply 

value range is: 100~240VAC/DC.

 

 

 

Dual power supply 

This  series  of  products  support  dual 

power  supply  scheme  and  provide  P1 

and  P2  independent  power  supply 

systems. When one of the power supply 

system  fails,  the  device  can  operate 

uninterruptedly and normally, which has 

improved  the  reliability  of  network  operation.  Power  supply 

value range is: 100~240VAC/DC.

 

 

Notes:

 

 

Power  ON  operation:  First  insert  the  power  supply 

terminal  block  into  the  device  power  supply  interface, 

and then plug the power supply plug contact and power 

on. 

 

Power  OFF  operation:  First  unpin  the  power  plug,  and 

then  remove  the  wiring  part  of  terminal  block,  please 

pay attention to the operation order above. 

Relay Connection

 

This  series  of  devices  provide  5  pins  5.08mm  pitch  terminal 

blocks;  power  supply  occupies  3  pins  on  the  left.  Relay 

terminals  are  a  pair  of  normally  closed  contacts  in  device 

alarm relay. They are open circuit in normal non alarm state, 

closed  when  power  off.  This  series  of single and dual  power 

supply  products  respectively  support  1  or  2  channels  relay 

alarm  output  and  down  alarm  of  power  supply.  Dual  power 

supply products will send out alarm when two power supplies 