3onedata ICS5028G Series User Manual Download Page 4

RUN 

ON/OFF 

System is not running well 

Blinking 

System is running well 

Alarm 

ON 

When the alarm is enabled, 

power or the port’s link is 

inactive. 

OFF 

Power and the port’s link is 

active, the alarm is disabled. 

Link/ACT 

(1~28) 

ON 

Port connection is active 

Blinking 

Data transmitted 

OFF 

Port connection is not active 

Installation

 

Before installation, confirm that the work environment meet the 

installation require, including the power needs and abundant 

space. Whether it is close to the connection equipment and other 

equipments are prepared or not.   

1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 

3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

4. Power: 100-240VAC power input 

5. Environment: working temperature: -40

75

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

Rack mount installation 

In most of industrial application, it is convenience to use rack 

mount installation, the step of installation is as follows: 

1.

 

Check if have rack mount installation tools and components 

(The package provided parts of components) 

2.

 

Check installation place strong or not, have the place to install 

the device or not. 

3.

 

Put the device into rack, aim at the screw hole of device and 

rack, fixed it in strong screw. Easy and convenience to 

operation. 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.

 

It is needed to check whether the type, quantity and 

specification of cable match the requirement before cable 

laying; 

2.

 

It is needed to check the cable is damaged or not, factory 

records and quality assurance booklet before cable laying; 

3.

 

The required cable specification, quantity, direction and 

laying position need to match construction requirements, and 

cable length depends on actual position; 

4.

 

All the cable cannot have break-down and terminal in the 

middle; 

5.

 

Cables should be straight in the hallways and turning; 

6.

 

Cable should be straight in the groove, and cannot beyond the 

groove in case of holding back the inlet and outlet holes. 

Cables should be banded and fixed when they are out of the 

groove; 

7.

 

User cable should be separated from the power lines. Cables, 

power lines and grounding lines cannot be overlapped and 

mixed when they are in the same groove road. When cable is 

too long, it cannot hold down other cable, but structure in the 

middle of alignment rack; 

8.

 

Pigtail cannot be tied and swerved as less as possible. 

Swerving radius cannot be too small (small swerving causes 

terrible loss of link). Its banding should be moderate, not too 

tight, and should be separated from other cables; 

9.

 

It should have corresponding simple signal at both sides of the 

cable for maintaining. 

Specification

 

Technology 

Standard:  IEEE802.3, IEEE802.3u, IEEE802.3z/ab,  IEEE802.3x, 

IEEE802.3ae,  IEEE802.1d, IEEE802.1w, IEEE802.1s, 

IEEE802.1q, IEEE802.1p, IEEE802.1x, IEEE802.3ad 

Flow control: IEEE802.3x flow control, Back Pressure flow 

control 

Protocol 

IGMP Snooping , GMRP, SNMPv1/v2/v3, QOS, 

STP/RSTP/MSTP, DHCP Server/Client, DHCP, VLAN, LLDP, 

SNTP, Telnet, HTTP/HTTPS, SSH, LACP 

Layer 3 Switching Technology 

Static routing, RIP V1/V2, OSPF, VRRP, BGP 

Interface 

RJ45 port: 10/100 /1000BaseT(X), flow control, full / half duplex, 

adaptive work mode, MDI/MDI-X adaptive 

Combo port: 1000Base-X SFP slot or 10/100/1000Base-T(X) 

Gigabit SFP port: 1000Base-X SFP slot 

10GbE SFP port: 10GbE SFP+ slot 

Console port: CONSOLE Admin Port (RJ45) 

Alarm port: 5-core 5.08mm wiring terminal (R+/R-), 

          2-way relay alarm output 

Transmission distance 

Twisted-pair: 100m (standard CAT5/CAT5e cable) 

Multi-mode fiber: 1310nm, 2km 

Single mode fiber: 1310nm, 20/40Km 

1550nm, 60/80/100/120Km 

LED indicator 

Power indicator: P1/P2 

Alarm indicator: ALM 

Operation indicator: RUN 

Port connection / operation status indicator: Link/ACT (1~28) 

Switch attribute: 

Transmission mode: store-and-forward 

MAC address: 16K 

Cache: 12Mb 

Switched Bandwidth: 128G 

1000M forwarding rate: 1488100pps 

10000M forwarding rate: 14881000pps 

- 4 - 

Summary of Contents for ICS5028G Series

Page 1: ...nt at a working temperature of 40 75 which can meet various industrial application requirements and provide reliable and economic solutions for Ethernet access Packing list The industrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch ⅹ 1 Documentation and...

Page 2: ...14 Power 2 input power socket 15 10 100 1000BaseT X or 1000Base SFP slot combo ports Power supply input The switch support dual redundant power supplies Power Supply 1 P1 and Power Supply 2 P2 The switch rear panel provides power sockets for AC100 240V power entered Socket diagram is as follows The redundant power can be used independently P1 and P2 can supply power at the same time once either of...

Page 3: ... TX PIN defines is as follows PIN MDI MDI X 1 BI_DA TX BI_DB RX 2 BI_DA TX BI_DB RX 3 BI_DB RX BI_DA TX 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB RX BI_DA TX 7 BI_DD BI_DC 8 BI_DD BI_DC Note 10Base T 100Base TX TX transmit data RX receive data not use 10 100Base T X MDI straight through cable 10 100Base T X MDI X Cross over cable Gigabit MDI straight through cable Gigabit MDI X Cross over cable MDI MDI ...

Page 4: ...own and terminal in the middle 5 Cables should be straight in the hallways and turning 6 Cable should be straight in the groove and cannot beyond the groove in case of holding back the inlet and outlet holes Cables should be banded and fixed when they are out of the groove 7 User cable should be separated from the power lines Cables power lines and grounding lines cannot be overlapped and mixed wh...

Page 5: ...28G 4TS 8GC Mechanical characteristics Shell IP30 protection metal shell Installation 19 rack mounted Weight 3 9kg Dimension L W H 440mm 285mm 43mm Working environment Working temperature 40 75 Storage temperature 40 85 Humidity 5 95 no condensation Industry Standard EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level 4 EN61000 4 4 EFT Level 4 EN61000 4 5 Surge Level 4 Shock IEC 60068 ...

Reviews: