Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
and then plug the power supply plug contact and power 
on. 

 

Power OFF operation: First, remove the power plug, 
and then remove the wiring section of terminal block. 
Please pay attention to the above operation sequence. 

Reset Button Setting

 

This device provides 1 reset button, press the button 
for 1-2S then release it to reboot the device; press the 
button for 5S then release it to restore factory defaults. 

Checking LED Indicator

 

The device provides LED indicators to monitor the device 
working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 
table as below: 

LED 

Indicate 

Description 

WIFI 

ON 

WIFI is running normally 

OFF 

WIFI is running abnormally 
or closed 

RUN 

ON 

The device is powered on 
or the device is abnormal. 

OFF 

The device is powered off 
or the device is abnormal. 

Blinking 

The device is running 
normally 

PWR 

ON 

PWR is connected and 
running normally 

OFF 

PWR  is disconnected and 
running abnormally 

Bridge 

OFF 

No bridging is established 

ON 

The strength of bridging 
signal is 70~100dBm 

1 time/1s Blinking 

The strength of bridging 
signal is 30~70dBm 

1 time/2s Blinking 

The strength of bridging 
signal is 1~30dBm 

Logging in to WEB Interface

 

This device supports WEB management and configuration. 
Computer can access the device via LAN. The way of logging 
in to device’s configuration interface via IE browser is shown 
as below: 
Step 1 

Configure the IP addresses of computer and the 
device to the same network segment, and the 
network between them can be mutually accessed 

Step 2 

Enter device’s IP address in the address bar of the 
computer browser. 

 

Step 3 

Enter device’s user name and password in the 
login window as shown below. 

 

Step 4 

Click “Login” button to login to the WEB interface of 
the device. 

Note: 

 

The default IP address of the device is “192.168.1.254”. 

 

The default user name and password of the device is 
“admin”. 

 

If the user name or password is lost, user can restore it 
to factory settings via restore button or management 
software; all modified configurations will be cleared 
after restoring to factory settings, so please backup 
configuration file in advance. 

 

Please refer to user manual for specific configuration 
method of logging in to WEB interface and other 

configurations about network management function.

 

Specification

 

Standard 

 

Standard 

IEEE802.3

IEEE802.3u

IEEE802.11b/g/n

IEEE802.11i

IEEE802.11r 

Panel 

 

Copper Port 

5 10/100Base-T(X) RJ45 
ports: 4 LAN + 1 WAN. 

Antenna pedestal 

2 WIFI IPEX-1 generation 
antenna pedestals, RP-SMA-K 
type (Female), support 1.5kV 
isolation protection 

Indicator 

Signal indicator, Running 
indicator, Power supply 
indicator, 2.4G wireless 
indicator 

WIFI Transmission Rate

   

802.11n 

6.5~300Mbps 

802.11b 

11/5.5/2/1Mbps 

802.11g 

54/48/36/24/18/12/9/6Mbps 

WIFI RF

 

 

Channel 

2.412GHz~2.4835GHz

 

RF power output 

23dBm

 

Modulation scheme 

DBPSK, DQPSK, CCK, 
OFDM, 16-QAM, 64-QAM 

WIFI Receiving 
Sensitivity 

 

802.11n_HT40 

-82dBm@MCS0

-64dBm@MCS7 

802.11n_HT20 

-85dBm@MCS0

-67dBm@MCS7 

802.11g 

-91dBm@6Mbps

-72dBm@54Mbps 

802.11b 

-93dBm@1Mbps

-87dBm@11Mbps 

WIFI Transmission 

 