3onedata IAC8500-1GC4GT Quick Installation Manual Download Page 3

 

Step 4 

Click “Login” button to login to the WEB interface of 
the device. 

Description: 

 

The default IP address of the device is “192.168.3.1”. 

 

The default user name and password of the device is 
“admin”. 

 

If the username or password is lost, user can restore it to 
factory settings via device DIP switch or management 
software; all modified configurations will be cleared 
after restoring to factory settings, so please backup 
configuration file in advance. 

 

Please refer to user manual for specific configuration 
method of logging in to WEB interface and other 
configurations about network management function. 

Specification

 

Panel 

 

Gigabit LAN port 

10/100/1000 Base-T(X) 
self-adapting RJ45 port, half/full 
duplex self-adaption support 
MDI/MDI-X self-adaption 

Gigabit WAN port 

Gigabit Combo, optional 
10/100/1000Base-T(X) and 
1000Base-X SFP 

Console Port

 

CLI command line management 
port (RS-232), RJ45(CLI function 
is reserved)

 

USB 2.0 port 

USB Type A female head 

USB 3.0 port 

USB Type A female head 

Alarm interface

 

2-pin 7.62mm pitch terminal block, 
support 1 relay alarm output

 

Indicator 

Power supply indicator, alarm 
indicator, running indicator, 
interface indicator 

Power supply

 

 

Input power supply

 

110~240VAC 50-60Hz 
Dual power supply redundancy, 
3A over-current protection

 

Access terminal 
block 

Power supply outlet with switch 

Power consumption 

 

No-load 

3.0W@220VAC

 

Full-load 

5.0W@220VAC

 

Working 
environment 

 

Working temperature

 

-40~75

 

Storage temperature

 

-40~85

 

Working humidity

 

5%

95% (no condensation) 

Protection grade 

IP30(metal) 

 