Specification

 

Panel 

 

100M Copper Port

 

10/100Base-T(X) 

self-adapting 

RJ45 port

 

Serial Port

 

  3IN1 

RJ45 interface or 

RS-485/422 terminal block with 
isolation

 

Indicator 

Power indicator, Running indicator, 
Copper port connection indicator, 
Serial port transmission and 
receiving data indicator 

Power supply

 

 

Input power supply

 

12

48VDC

 

Access terminal block  3-pin 5.08mm pitch terminal blocks

 

Power consumption 

 

Model I

 

No-load: 1.80W@12VDC 
Full-load: 3.90W@12VDC

 

Model II

 

No-load: 3.16W@12VDC 
Full-load: 3.72W@12VDC 

Working 
environment 

 

Model I 

Operating temperature: -40~75

 

Storage temperature:-40~85

 

Model II 

Operating temperature: -40~70

 

Storage temperature:-40~70

 

Working humidity 

5%

95% (no condensation) 

Protection grade 

IP30(metal) 

 

 

Summary of Contents for GW1118 Series

Page 1: ...ble x1 8 Warranty card x1 9 Foot pad x4 If any of these items are damaged or lost please contact our company or dealers we will solve it ASAP Product Overview The series products are MODBUS gateway devices Models are as follows Model I GW1118 8D 3IN1 8 RS 485 422 232 serial ports 2 100M copper port Model II GW1118 8DI RS 485 8 RS 485 422 serial port with isolation 2 100M copper port Panel Design T...

Page 2: ...ence installation dimension mark 2 bolt positions on the wall Step 3 Nail M4 screws on the wall and keep 2mm interspace reserved Step 4 Hang the device on two screws and slide downward then tighten the screw to enhance stability mounting ends Wall mounted Device Disassembling Step 1 Device power off Step 2 Unscrew the screw on the wall about 2mm Step 3 Lift the device upward slightly take out the ...

Page 3: ...ing abnormally LINK 1 2 ON Copper port has established an active network connection Blinking Copper port is in a network activity state OFF Copper port has not established an active network connection TX 1 8 OFF No data or abnormal data is being transmitted through serial port Blinking Serial port is transmitting data RX 1 8 OFF Serial port is not receiving data or receiving data abnormally Blinki...

Page 4: ...Running indicator Copper port connection indicator Serial port transmission and receiving data indicator Power supply Input power supply 12 48VDC Access terminal block 3 pin 5 08mm pitch terminal blocks Power consumption Model I No load 1 80W 12VDC Full load 3 90W 12VDC Model II No load 3 16W 12VDC Full load 3 72W 12VDC Working environment Model I Operating temperature 40 75 Storage temperature 40...

Reviews: