background image

and then remove the wiring section of terminal block. 
Please pay attention to the above operation sequence. 

E1 Port Connection

 

The device provides 1 E1 port, interface type is BNC or RJ45, 

interface impedance is 75 Ω unbalanced (BNC) and 120 Ω 

balance (RJ45), supports interface 1500V electromagnetic 

isolation protection. 120 Ω RJ45 pins are defined as follows:

 

Pin No. 

Function definition 

Signal 
direction 

1. 

NC (reserved) 

2. 

RX+ (positive received data)  Input   

3. 

RX- (received data negative)  Input 

4. 

GND (Ground) 

5. 

GND (Ground) 

6. 

TX+ (sending data positive ) 

Output 

7. 

TX- (sending data negative) 

Output 

8. 

NC (reserved) 

RS-232 Connection

 

The device provides 1 RS-232 interface 
in the form of DB25 female head, which 
can be connected to the RS-232 device 
through the converter wire of DB25 

male head to DB9 female head. The interface supports 600W 
surge protection and 15KV static protection. The pin 
definitions of RS-232 are shown as follows: 

Pin No. 

Function 
definition 

Signal direction 

2.

 

TXD

 

Input 

3.

 

RXD

 

Output 

5.

 

CTS

 

Output 

6.

 

DSR

 

Output 

7.

 

GND

 

8.

 

DCD

 

Output 

DIP Switch

 

The device provides 1 set of DIP switch for 
impedance, BNC grounding, clock, loopback 
and factory setting. The functions are 

defined as follows. 
The settings of SW1 are as follows: 

Category 
setting 

DIP bit  Set the DIP to 

OFF 

Set the DIP to 
ON 

Impedance  Bit 1 

120 ohm   

75 ohm   

BNC 
Grounding 

Bit 2 

No Grounding 

OUT port 
grounding 

Bit 3 

No Grounding 

IN Grounding 

Clock 

Bit 4 

Internal Clock 

Line recovery 
clock 

Loopback    Bit 8 

No loopback 

E1 Loopback 

Bit 9 

No loopback 

RS-232 
Loopback 

Bit 10 

Reserved 

Reserved 

Restore Factory Settings 
Bit 1 

Bit 2 

Bit 3 

Bit 4 

Bit 5 

ON 

OFF 

OFF 

ON 

OFF 

Bit 6

 

Bit 7

 

Bit 8

 

Bit 9

 

Bit 10 

OFF 

OFF 

OFF 

OFF 

OFF 

Indicator

 

The device provides LED indicators to monitor the device 
working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 
table as below:

 

LED 

Indicate  Description 

PWR 

ON

 

The power supply is running 
normally 

OFF

 

Power supply is disconnected 
or running abnormally 

LOS 

ON 

E1 interface receives no code 

AIS 

ON 

E1 interface receives full 1 code 

ERR 

ON 

E1 link interrupt 

TD 

ON 

Data received successfully 

RD 

ON 

Data sent successfully 

Notice: 

Whether AIS alarm is caused by a line fault, depends on 
the actual situation. For example, when E1 port uses 
non-similar HDLC protocol, when data communication 
is not conducted, the whole 1-code signal must appear 
on the line, and the AIS indicator will alarm. Just as 
when the device was just powered on, the line not 
connected to the E1 port was full 0 codes, and the AIS 
light was not on. If the E1 port was carried on the outer 
loop, then the E1 port was full 1 code, and the E1 light 
would be naturally on. 

Specification

 

Panel 

 

RS-232 

1 RS-232, DB25 female head 

E1 Interface 

1 E1, BNC or RJ45, 75 Ω 
unbalanced (BNC) and 120 Ω 

balance (RJ45) 

Indicator 

Power indicator, losing 
synchronization alarm 
indicator, upstream E1 link full 
1-code alarm indicator, E1 link 
interrupt alarm indicator, data 
receiving indicator from G.703 
network, data sending 
indicator to G.703 network 

Power Supply

 

 

Power input

 

220VAC   

Terminal block 

AC power supply outlet with 
switch; 

Power Consumption 

 

Full-load 

2W 

Working Environment 

 

Working temperature

 

-25~70

 

Storage temperature

 

-40~85

 

Working humidity

 

5%

95% (no condensation) 

 