background image

 

Check if the DIN-Rail mounting kit is installed firmly. 

Step 1

 

Insert the bottom of DIN-Rail mounting kit (one side 

Step 2

with  spring  support)  into  DIN-Rail,  and  then  insert 

the top into DIN-Rail. 

Tips: 

Insert a little to the bottom, lift upward and then insert 

to the top. 

 

Check and confirm the product is firmly installed on 

Step 3

DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

 

 

Device power off. 

Step 1

 

After lift the device upward slightly, first shift out the 

Step 2

top  of  DIN-Rail  mounting  kit,  then  shift  out  the 

bottom of DIN-Rail, disassembling ends. 

Notes before powering on: 

 

Power ON operation: first connect power line to the 

connection terminal of device power supply, then power 

on. 

 

Power OFF operation: first unpin the power plug, then 

remove the power line, please note the operation order 

above. 

Power Supply Connection

 

 

DC power supply 

The device provides 6-pin 5.08mm pitch 

input terminal blocks, including 4-pin 

power supply terminal blocks on the left 

side. It provides two independent DC 

power supply systems for P1 and P2. The 

power supply has anti-reverse function. 

Power supply input voltage: 48VDC 

Relay Connection

 

The device provides 6-pin 5.08mm pitch 

input terminal blocks, including 2-pin 

relay terminal blocks on the right side.   

Relay terminals are a pair of normally 

open contacts in device alarm relay. 

They are open circuit in normal non alarm state, closed when 

any alarm information occurs. Such as: it's closed when power 

off, and send out alarm. The switch supports 1 channel relay 

alarm information output, support DC power alarm information 

or network abnormal alarm output, it can be connected to 

alerting lamp, alarm buzzer, or other switching value collecting 

devices for timely warning operating staffs when alarm 

information occurs. 

DIP Switch Settings

 

Provide 4-bits DIP switch for function setting, 

where "ON" is enable valid terminal. Please 

power off and power on after changing the status 

of DIP switch. DIP switch define as follow: 

1. 

Reserved 

2. 

Restore factory setting 

3. 

Upgrade 

4. 

Reserved 

Console Port Connection

 

The  device  provides  1  channel  procedure  debugging  port 

based  on  serial  port,  and  can  conduct  device  CLI  command 

line management after connected to PC. The interface adopts 

RJ45 port, the RJ45 pin definition is as follows: 

Pin No. 

Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

The function of each LED is described in the table as below:   

LED 

Status 

Description 

P1 

ON 

PWR1 is 

connected and 

running normally 

OFF 

PWR1 is 

disconnected and 

running 

abnormally. 

P2 

ON 

PWR2 is 

connected and 

running normally 

OFF 

PWR2 is 

disconnected and 

running 

abnormally 

ALM 

ON 

Power supply, 

port link alarm 

OFF 

Power supply, 

port link without 

alarm 

RUN 

ON 

The device is 

powered on or 

the device is 

abnormal. 

OFF 

The device is 

powered off or 

the device is 

abnormal. 

Blinking 

System is 

running well. 

Link/ACT 

(1-8, G1-G2) 

ON 

Ethernet port 

connection is 

active. 

Blinking 

Data transmitted 

OFF 

Ethernet port 

connection is 

inactive. 

POE (1-8) 

ON 

POE port supply 

electricity for 

other devices 

normally 

OFF 

POE is disabled 

or disconnected 

Logging in to WEB Interface

 

This  device  supports  WEB  management  and  configuration. 

Computer  can  access  the  device  via  Ethernet  interface.  The 

way  of  logging  in  to  device

’s  configuration  interface  via  IE 

browser is shown as below: 

 

Configure  the  IP  addresses  of  computer  and  the 

Step 1

device  to  the  same  network  segment,  and  the 

network between them can be mutually accessed. 

Reviews: