3One data IES608-2F Hardware Installation Manual Download Page 3

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

1.

Grounding screw

2. PWR1/PWR2 input, relay output

6 bit terminal block

3. DIP switch: DOWNLOAD PROGRAM,

RESUME DEFAULT, SW-Ring Enabled

4. DOWNLOAD PROGRAM port

(RS-232, RJ45)

5. Heat dissipation orifices

6. DIN-Rail locating kit

top

top

top

top panel

panel

panel

panel

7. Screw hole for wall mounting kit

8. 10/100Base-T(X) port

9. Corporation, product information

10. Run indication LED

11. Power input PWR1 LED

12. Power input PWR2 LED

13. System alarm indication LED

14. Fiber port 8 indication LED

15. Fiber port 7 indication LED

16. 100Base-FX port

back

back

back

back panel

panel

panel

panel

Units

Units

Units

Units

mm

mm

mm

mm

Summary of Contents for IES608-2F

Page 1: ...ng QoS VLAN Port Trunking velocity configuration and alarm enabling functions To satisfy applications in different industrial environments IES608 2F series can also provide wide temperature type in ac...

Page 2: ...l load 3 Port based VLAN IEEE 802 1Q VLAN to ease network planning 4 Port Trunking for optimum bandwidth utilization 5 Lock port function for blocking unauthorized access based on MAC address 6 Port m...

Page 3: ...5 Heat dissipation orifices 6 DIN Rail locating kit top top top top panel panel panel panel 7 Screw hole for wall mounting kit 8 10 100Base T X port 9 Corporation product information 10 Run indicatio...

Page 4: ...used 100 of UTP 5 10Mbps is used 100 of UTP 3 4 5 RJ 45 port support automatic MDI MDI X operation can connect the PC Server Converter and HUB Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6...

Page 5: ...in pair TX transmit port connect remote switch s RX receive port RX receive port connect remote switch s TX transmit port The optical fiber connection supports the line to instruct enhance the reliabi...

Page 6: ...d to power input POWER2 input Alarm Alarm Alarm Alarm ON When the alarm is enabled power and the port s link is inactive OFF Power and the port s link is active not not not not alarm Run Run Run Run O...

Page 7: ...the DC power inputs or 2 One of the ports for which the corresponding Port alarm DIP Switch is set to ON is not properly connected If neither of these two conditions occur the alarm circuit will be c...

Page 8: ...allation require including the power needs and abundant space whether it is close to the connection equipment and other equipments are prepared or not Installation Installation Installation Installati...

Page 9: ...ximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiri...

Page 10: ...tional Wavelength 850nm 1310 nm 1550nm DOWNLOAD PROGRAM Port Based serial network management RS 232 RJ45 Alarm output interface One relay alarm output Support power port link and ring network alarm In...

Page 11: ...condensing Approvals Approvals Approvals Approvals Warranty Warranty Warranty Warranty 5 5 5 5 years years years years Certifications Certifications Certifications Certifications Shenzhen Shenzhen She...