MULTIPLE SYSTEM INSTALLATION RULE
POWER LINE CABLING
False alarm due to conducted noise on the power lines can be avoided if the power lines are filtered
every 4-6 meters and use twin-core shielded cable.
This is done already on A M 0 4 - 1 . But the power line between the antennas is not longer than 6
meters (8.2 MHz). Additional filter boards must be use if the length of the power cable between the
antennas is longer than 6 meters, .
AM04-1 uses a built-in filter, but it only protect the electronics its self. It do not contribute to the
filtering of the power output. So, two antennas using a same power supply is ideal.
All antennas must face to same direction to have same phase.
This will avoid detection dead zone at the middle of two antennas.
That means you are no longer required to change the timing jumper on each AM04-1 PCB or
connect synchro cable to allow multiple systems to operate in close proximity to each other.
Auto timing program allows maximum 63 AM04-1operate together without requiring them to be
slaved to or synchronized to each other.
S A M E F R E Q U E N C Y I N T E R F E R E N C E
AM04-1
is now operate in a higher noise environment without reducing the detection range. It is
possible to reduce interfere from other swept system or deactivator.
8
MULTIPLE SYSTEM SYNCHRONIZATION
The AM04-1
software now automatically selects the "AM04-1" synchro timing.