![3M Wrist Strap and Ground Monitor 773 User Manual Download Page 8](http://html1.mh-extra.com/html/3m/wrist-strap-and-ground-monitor-773/wrist-strap-and-ground-monitor-773_user-manual_442868008.webp)
8
Section 2.0 Installation
Supplied Parts
The 3M
™
Wrist Strap and Ground Monitor 773 is supplied with the following items:
User’s Guide, AC/DC Adapter
Wire Attachment
Attach 18 AWG wires to the unit as described
below. Strip back the vinyl insulation at each
end of the wires to approximately ¹/³ inch
(8 mm). Twist the stranded wire on each end
before inserting the wire into each connector
location. In order to attach the wire, insert a small blade screwdriver into the orange
slot above. Gently push inward and insert the stripped wire fully into the hole in the
green connector. Hold the wire fully in and release the screwdriver to allow the wire
to catch.
Attach the ground wire to the “GND” connector on back of unit.
Attach the impedance monitor wire(s) to the chosen ground lines “G1, G2”
connector(s) on the back of the unit. Insert the wire as described above.
If you are planning to use the 773 monitor output to the tool, attach the wire to the
“Out” connector on the back of the unit. Insert the wire as described above.
AC/DC Adapter Connection
Connect the circular plug of the AC/DC Adapter into the power jack on the back of
the unit.