background image

2

3M™ Water Filtration Systems

Installation and Operating Instructions

Specifications

Inlet Size: 1/4” John Guest

®

 Fitting

Outlet Size: 1/4” John Guest Fitting

Temperature Range: 40-100°F (4.4-38°C)

Pressure Range: 25-120 psi (172-827 kPa)

Dimensions - 2 3/4" W x 2 3/8" D x 12 1/2" H

 

(7.0 cm x 6.0 cm x 31.75 cm)

Parts Included

Filter Cartridge, System Head/Bracket Assembly

Installation Precautions

Warning: Do not use with water that is microbiologically 

unsafe or of unknown quality without adequate disinfection 

before  or  after  the  system.  Systems  certified  for  cyst 

reduction  may  be  used  on  disinfected  waters  that  may 

contain filterable cysts.

Caution: System must be protected from freezing. 

Drain filter when room temperature drops below 

40°F (4.4°C).

Caution: Do not install on hot water line. Maximum 

temperature is 100°F (38°C).

•  Do not use torch or other high temperature 

  sources near filter or plastic cartridge.

•  Do not install near electric wires or water pipes 

  that will be in the path of the drill when selecting 

  the position to mount bracket.

•  Do not install in direct sunlight.

•  Allow minimum of 2” (5 cm) clear space under 

  filter to facilitate cartridge change.

•  Mount filter in such a position as to prevent it from 

  being struck by other items.

•  Installation must comply with existing state or 

  local plumbing codes.

12.5”

(31.75 cm)

2 3/4”

(6.9 cm)

2 1/4”

(5.7 cm)

14.8”

(37.7 cm)

Cartridge Removed

Cartridge Installed

Figure 1

Reviews: