3M™ Water Filtration Systems
Installation and Operating Instructions
Specifications
Inlet Size: 1/4” John Guest
®
Fitting
Outlet Size: 1/4” John Guest Fitting
Temperature Range: 40-100°F (4.4-38°C)
Pressure Range: 25-120 psi (172-827 kPa)
Dimensions - 2 3/4" W x 2 3/8" D x 12 1/2" H
(7.0 cm x 6.0 cm x 31.75 cm)
Parts Included
Filter Cartridge, System Head/Bracket Assembly
Installation Precautions
Warning: Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may
contain filterable cysts.
Caution: System must be protected from freezing.
Drain filter when room temperature drops below
40°F (4.4°C).
Caution: Do not install on hot water line. Maximum
temperature is 100°F (38°C).
• Do not use torch or other high temperature
sources near filter or plastic cartridge.
• Do not install near electric wires or water pipes
that will be in the path of the drill when selecting
the position to mount bracket.
• Do not install in direct sunlight.
• Allow minimum of 2” (5 cm) clear space under
filter to facilitate cartridge change.
• Mount filter in such a position as to prevent it from
being struck by other items.
• Installation must comply with existing state or
local plumbing codes.
12.5”
(31.75 cm)
2 3/4”
(6.9 cm)
2 1/4”
(5.7 cm)
14.8”
(37.7 cm)
Cartridge Removed
Cartridge Installed
Figure 1