background image

1

1

2

2

To Release Tubing 

To Attach Tubing 

Push tubing straight in as far
as it will go.

Tubing is secured in.

Push in collt to release tubing.

Pull tubing straight out.

Step 2

Step 3

Step 4

Step 1

This product is outfitted with a user friendly ‘Push In’ connector at the vent valve. Proper use of the connectors is 
shown in the figure below. It is most important that the tubing selected for use with these connectors be of high  
quality, exact size and roundness, and with no surface nicks or scratches.  If it is necessary to cut the tubing, use a 
plastic tubing cutter or sharp razor knife. Make a clean square cut. Should a leak occur at a "Push-In" connec-
tor, the cause is usually a problem with tubing.

To Fix:   
 

 

1. Relieve pressure  

2. Release tubing    

3. Cut off at least 1/4” from end   

 

4. Reattach tubing   

5. Confirm connection is leak free

How to Use “Push-in” Connectors

 

This product is outfitted with inlet/outlet fittings. The fittings can be attached or removed from the system with-  

 

out tools. Retention clips are semi-circular in shape with three internal tabs, bottom, center and top. Tab interfaces   

 

with windows in the manifold head near each connection port clip is flexible and easily assembled following these  

 

instruction and illustrations.

 

 

1. Insert fitting into manifold.

 

 

2. With fitting inserted into manifold port, snap clip into place beginning at the bottom window

 

 

3. Push center tab into center window.

 

 

4. Finally push top tab into top window.

How to Use the Inlet/Outlet Fitting and Retention Clips 

5

Equipment Installation

CAUTION

T

o reduce the risk associated with property damage due to water leakage:

 

t

Do not

 use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic 

       plumbing.

t0OQMBTUJDmUUJOHTOFWFSVTFQJQFTFBMBOUPSQJQFEPQF6TF15'&UISFBEUBQF

only

, pipe dope properties may 

       deteriorate plastic.

 

t

Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtight-        

       ening occurs..

 

t%POPU

install near water pipes which will be in path of a drilling tool when selecting the position to mount the system

 t

Mount filter in such a position as to prevent it from being struck by other items used in the area of installation.

 t

Ensure that the location and fasteners will support the weight of the system when installed.

 

t

Ensure all tubing and fittings are secure and free of leaks.

Summary of Contents for Triple Manifold Water Filtration Systems

Page 1: ...Installer Please leave this manual with owner operator Dual Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems 3MTM Water Filtration Products...

Page 2: ...dicates a potentially hazardous situation which if not avoided may result in minor or moderate injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided ma...

Page 3: ...s condition t Do not use a torch or other high temperature sources near lter system cartridges plastic ttings or plastic plumbing t 0O QMBTUJD mUUJOHT OFWFS VTF QJQF TFBMBOU PS QJQF EPQF 6TF 15 UISFBE...

Page 4: ...ridge 24 1 16 63 66 cm HF6X Series Cartridge 18 1 16 45 9 cm HF4X Series Cartridge 15 1 16 38 3 cm Triple Manifold Filtration System Product Dimensions 22 7 8 in 58 10 cm 13 65 cm 5 3 8 in To Remove C...

Page 5: ...rfaces with windows in the manifold head near each connection port clip is exible and easily assembled following these instruction and illustrations 1 Insert tting into manifold 2 With tting inserted...

Page 6: ...rear and outlet right front ttings to the manifold The inlet kit includes the tting a ball valve and a nipple The outlet is a tting only The instructions for the retention clips are on page 4 6 Remove...

Page 7: ...small amount of water will drain from manifold as cartridge is removed 6 Remove sanitary cap from new cartridge Install cartridge with a quarter turn to the right until cartridge comes to a complete...

Page 8: ...nlet outlet ttings 6 63597320 o ring 1 Seal inlet outlet ttings 7 6220505 Inlet tting kit 1 Inlet tting with ball valve 8 6220506 Outlet tting kit 2 Outlet tting 9 60 235380 x ball valve 1 Inlet water...

Page 9: ...20 o ring 1 Seal inlet outlet ttings 7 6220505 Inlet tting kit left rear 1 Inlet tting with ball valve 9 6220507 Outlet tting kit right front 1 outlet tting 10 60 235380 Pressure Gauge optional 1 Inle...

Page 10: ...ing the warranty period 3M Puri cation Inc at it s option will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Custo...

Page 11: ...11...

Page 12: ...pany All rights reserved 34 8712 8017 7 Please Recycle Printed in U S A 3M Puri cation Inc 400 Research Parkway Meriden CT 06450 USA Toll Free 866 990 9785 Worldwide 203 237 5541 Fax 203 238 8701 www...