3M™ PROTÉGÉ SG
PORTABLE, REUSABLE, SINGLE-GAS MONITOR
CONFIGURATION AND SETUP
087-0065, Rev D/February 2019
4-5
4. The PGD Application Software dashboard will display, and the connected monitor is shown (see
).
Figure 4-7: Connected Monitors
4.4. Default Settings
Factory Default Alarm Setpoints
default settings of the monitor.
NOTE: The user can configure alarm setpoints and the firmware settings via the PGD Appli-
cation software. Refer to the Portable Gas Detection (PGD) Application User Guide
(P/N 087-0061)
Table 4-2: Factory Default Alarm Setpoints
Gas
Range
TWA
STEL
Low
High
Gas Type &
Value for CAL
O
2
0% -30%
N/A
N/A
19.5%
23.5%
Zero air
H
2
S (Standard)
0 - 500ppm
10ppm
15ppm
10ppm
15ppm
25ppm H
2
S
H
2
S (High
Resolution)
0 - 100ppm
1ppm
5ppm
1ppm
5ppm
25ppm H
2
S
CO (Standard)
0 - 1000ppm
35ppm
200pp
m
35ppm
200pp
m
50ppm CO