Table 1  –  Inspection Schedule

Type of Use

Application 

Examples

Conditions of Use

Inspection Frequency

Competent Person

User

Infrequent to Light

Rescue and 

Confined 

Space, Factory 

Maintenance

Good Storage Conditions, Indoor or Infrequent 

Outdoor Use, Room Temperature, Clean 

Environments

Annually

Before 

each use

Moderate to Heavy

Transportation, 

Residential 

Construction, 

Utilities, 

Warehouse

Fair Storage Conditions, Indoor and Extended 

Outdoor Use, All Temperatures, Clean or 

Dusty Environments

Semi-Annually  

to Annually

Before 

each use

Severe to 

Continuous

Commercial 

Construction, Oil 

and Gas, Mining

Harsh Storage Conditions, Prolonged or 

Continuous Outdoor Use, All Temperatures, 

Dirty Environment

Quarterly to  

Semi-Annually

Before 

each use

2.6  LOCKING SPEED:

 Situations which do not allow for an unobstructed fall path should be avoided. Working 

in confined or cramped spaces may not allow the body to reach sufficient speed to cause the SRL to lock if a 

fall occurs. Working on slowly shifting material, such as sand or grain,may not allow enough speed buildup 

to cause the SRL to lock. A clear path is required to assure positive locking of the SRL.

2.7  NORMAL OPERATIONS:

 Normal operation will allow the full length of the lifeline to extend and retract 

with no hesitation when extending and no slack when retracting as the worker moves at normal speeds. If a 

fall occurs, a speed sensing brake system will activate, stopping the fall and absorbing much of the energy 

created. For falls which occur near the end of the lifeline travel, a reserve lifeline system or Load Indicator 

has been incorporated to assure a reduced impact fall arrest. If the SRL has been subjected to fall forces, 

remove the SRL from service, mark 

“UNUSABLE”,

 and dispose of in the recommended manner (see 

“Section 

5.4 - Disposal”

). Sudden or quick movements should be avoided during normal work operation, as this may 

cause the SRL to lock up.

2.8  FREE FALL:

 When anchored overhead, SRLs will limit the free fall distance to 2 ft. (61 cm) or less. To avoid 

increased fall distances, anchor the SRL directly above the worker. Avoid working where your lifeline may 

cross or tangle with that of another worker. Avoid working where an object may fall and strike the lifeline; 

resulting in loss of balance or damage to the lifeline. Do not allow the lifeline to pass under arms or 

between legs. Never clamp, knot, or prevent the lifeline from retracting or being taut. Avoid slack line. 

Do not lengthen SRL by connecting a lanyard or similar component without consulting 3M Fall 

Protection.

2.9  FALL CLEARANCE:

 Figure 3A illustrates Fall Clearance requirements. Ensure adequate clearance exists in the fall 

path to prevent striking an object during a fall. If the worker will be working at a position that is not directly below 

the SRL anchorage point, the clearance required and vertical fall distance will be greater.

2.10  SWING FALLS:

 Swing falls occur when the anchorage point is not directly above the point where a fall 

occurs (see Figure 3B). The force of striking an object in a swing fall may cause serious injury. In a swing 

fall, the total vertical fall distance will be greater than if the user had fallen directly below the anchorage 

point, thus increasing fall clearance required to safely arrest the user. Use Figure 3A to determine the fall 

clearance for your application. Minimize swing falls by working as directly below the anchorage point as 

possible. Never permit a swing fall if injury could occur.

2.11 HAZARDS:

 Use of this equipment in areas where surrounding hazards exist may require additional precautions to 

reduce the possibility of injury to the user or damage to the equipment. Hazards may include, but are not limited 

to: high heat, caustic chemicals, corrosive environments, high voltage power lines, explosive or toxic gases, 

moving machinery, sharp edges, or overhead materials that may fall and contact the user or fall arrest system.

2.12  SHARP EDGES:

 Avoid working where the lifeline will be in contact with or abrade against unprotected sharp 

edges. Where contact with a sharp edge is possible, cover the edge with a protective material.

2.13  BODY SUPPORT:

 A Full Body Harness must be used with the Self Retracting Lifeline. The harness 

connection point must be above the user’s center of gravity. A body belt is not authorized for use with the 

Self Retracting Lifeline. If a fall occurs when using a body belt it may cause unintentional release and possible 

suffocation because of improper body support.

2.14  COMPATIBILITY OF COMPONENTS:

 Unless otherwise noted, 3M Fall Protection equipment is designed for 

use with 3M Fall Protection approved components and subsystems only. Substitutions or replacements made 

with non approved components or subsystems may jeopardize compatibility of equipment and may affect 

safety and reliability of the complete system.

IMPORTANT:

 Read and follow manufacturer’s instructions for associated components and subsystems in your 

personal fall arrest system.

Summary of Contents for Protecta series

Page 1: ...arabiner B Steel Snap Hook C Steel Swiveling Snap Hook D Steel Rebar Hook Swivel End Lifeline End Model Swivel End Lifeline End A 2000192 Optional Single SRL Models B C D ANSI 3100400 1 3100401 1 3100...

Page 2: ...Before using this equipment record the product identification information from the ID label in the inspection and maintenance log of this manual DESCRIPTIONS Figure 2 illustrates key components of the...

Page 3: ...2 in 1 07 m 2 3 ANCHORAGE Anchorages selected for fall arrest systems shall have a strength capable of sustaining static loads applied in the directions permitted by the system of at least 1 5 000 lbs...

Page 4: ...ifeline from retracting or being taut Avoid slack line Do not lengthen SRL by connecting a lanyard or similar component without consulting 3M Fall Protection 2 9 FALL CLEARANCE Figure 3A illustrates F...

Page 5: ...f clearance is required when the Rebel unit is anchored 3 1 2 ft 1 m above and 3 1 2 ft 1 m to the side of the user s harness dorsal connection NOTE The clearances provided above assume the fall occur...

Page 6: ...features that protrude from the snap hook or carabiner catch on the anchor and without visual confirmation seems to be fully engaged to the anchor point D To each other E Directly to webbing or rope...

Page 7: ...Snap Hook Twin SRL Harness Mounting using a Carabiner Some Rebel SRL models include a Carabiner identified in Figure 2 which can connect two Rebel SRLs to a Full Body Harness when climbing applicatio...

Page 8: ...nnections for Rebel SRL Fall Arrest Systems When using a hook to make a connection ensure roll out cannot occur see Figure 4 Do not use hooks or connectors that will not completely close over the atta...

Page 9: ...L and horizontal system components must be compatible Horizontal systems must be designed and installed under the supervision of a qualified engineer Consult the horizontal system equipment manufactur...

Page 10: ...10 Figure 8 Rebel SRL System Connections B C A E C E B A C B C A Dorsal D Ring B Carabiner C Snap Hook D Rebar Hook E Anchorage Point Figure 9 100 Tie Off Figure 10 Incorrect Attachment 1 2 3...

Page 11: ...housing causing a potential free fall hazard IMPORTANT If the lifeline contacts acids or other caustic chemicals remove the SRL from service and wash with water and a mild soap solution Inspect the S...

Page 12: ...uts and abrasions The lifeline must be free of knots throughout its length Inspect for excessive soiling paint build up and rust staining Inspect for chemical or heat damage indicated by brown discolo...

Page 13: ...13 Figure 14 Labeling...

Page 14: ...ON DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved...

Page 15: ...nstalaciones para evaluar los reclamos sobre la calidad Esta garant a no cubre los da os ocasionados por el desgaste el abuso el mal mantenimiento o como consecuencia del traslado del producto u otros...

Page 16: ...3Mfallprotection ca mmm com EMEA Europe Middle East Africa EMEA Headquarters 5a Merse Road North Moons Moat Redditch Worcestershire B98 9HL UK Phone 44 0 1527 548 000 Fax 44 0 1527 591 000 informatio...