Table 1  – 

Product Specifications

Connector Specifications:

Figure 1

Reference

Model Number

Description

Material

Gate Opening

Gate Strength

C1

2109193

Rebar Hook

Zinc-Plated Steel 

2.5 in. (63 mm)

3,600 lbf (16 kN) 

C2

9502116

Snap Hook

Zinc-Plated Steel

0.75 in. (19 mm)

3,600 lbf (16 kN)

C3

2000023

Carabiner

Aluminum

0.75 in. (19 mm)

3,600 lbf (16 kN)

C4

2000209

Rebar Hook

Aluminum, Steel 

2.38 in. (60 mm) 

3,600 lbf (16 kN)

C5

2000210

Rebar Hook

Zinc-Plated Steel

2.38 in. (60 mm)

3,600 lbf (16 kN)

C6

2000214

Rebar Hook

Aluminum, Steel 

2.5 in. (63mm)

3,600 lbf (16 kN)

C7

9502058

Rebar Hook

Aluminum

2.25 in. (57 mm) 

3,600 lbf (16 kN)

C8

9502195

Swivel Snap Hook

Zinc-Plated Steel

0.75 in. (19 mm)

3,600 lbf (16 kN)

C9

9505254

Snap Hook

Aluminum, Steel

0.75 in. (19 mm)

3,600 lbf (16 kN)

C10

2000125

Rebar Hook

Zinc-Plated Steel

3.0 in. (76 mm)

3,600 lbf (16 kN)

C11

2000118

Rebar Hook

Zinc-Plated Steel

2.5 in. (63 mm)

3,600 lbf (16 kN)

C12

9501804

Snap Hook

Zinc-Plated Steel

0.75 in. (19 mm)

5,000 lbf (22 kN)

 

;

Tensile Strength:

 The tensile strength of each of the connectors listed above is 22.2 kN (5,000 lbf).

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

C11

C12

Performance - SRD-LEs

ANSI/OSHA Models

OSHA Models

Capacity Range:

130 lb. - 220 lb.

(59 kg - 100 kg)

221 lb. - 310 lb.

(101 kg - 140 kg)

311 lb. - 420 lb.

(141 kg - 191 kg)

Maximum Arresting Force:

1,350 lbf (6 kN)

1,350 lbf (6 kN)

1,800 lbf (8 kN)

Average Arresting Force:

900 lbf (4 kN)

900 lbf (4 kN)

N/A

Maximum Arrest Distance:

*Assumes the SRD is mounted directly above the user.

42 in (1.1 m)

42 in (1.1 m)

48 in. (1.2 m)

Minimum Fall Clearance Required:

Vertical: 6 ft. (1.8 m)

Horizontal: 11.5 ft. (3.5 m)

Vertical: 7 ft. (2.1 m)

Horizontal: 14 ft. (4.3 m)

9 ft. (2.1 m)

Maximum Free Fall:

*SRD must be mounted above user’s D-ring.

2 ft. (0.6 m)

2 ft. (0.6 m)

2 ft. (0.6 m)

Maximum Free Fall - LE:

*Measured from user’s D-ring to working surface.

5 ft. (1.5 m)

5 ft. (1.5 m)

Not available for use in this 

format.

Summary of Contents for NANO-LOK 3500276

Page 1: ...rs Lifeline Extended Length X Working Length WL B 3500276 2 C5 DP1 8 ft 2 4 m 5 7 ft 1 7 m 3500277 2 C4 DP1 8 ft 2 4 m 5 7 ft 1 7 m 3500278 2 C1 DP1 7 3 ft 2 2 m 4 7 ft 1 4 m 3500279 2 C2 DP1 8 ft 2 4...

Page 2: ...terials e g sand or grain or within confined spaces or limited spaces may not allow the worker to reach sufficient speed to lock the SRD Avoid sudden or quick movements during work operation because t...

Page 3: ...re 2 identifies key components of the available SRD models In a standard SRD the Lifeline A extends and retracts from within the Housing B The Top Connector D secures the SRD to the designated attachm...

Page 4: ...is attached to an anchorage the strengths stated above must be multiplied by the number of systems attached to the anchorage See ANSI ASSP Z359 2 for more information Anchorage must be approved by a...

Page 5: ...N C11 2000118 Rebar Hook Zinc Plated Steel 2 5 in 63 mm 3 600 lbf 16 kN C12 9501804 Snap Hook Zinc Plated Steel 0 75 in 19 mm 5 000 lbf 22 kN Tensile Strength The tensile strength of each of the conne...

Page 6: ...ated maximum capacity component For example if your connecting subsystem has a capacity that is less than your harness you must comply with the capacity requirements of your connecting subsystem See t...

Page 7: ...reater C In a false engagement where size or shape of the connector or connecting element is not compatible and without visual confirmation would seem to be fully engaged D To each other E Directly to...

Page 8: ...leration device until stopping Harness Stretch HS is the amount of slack extending from the user s harness when the user is suspended by their harness attachment element Safety Factor SF is a set amou...

Page 9: ...6 2 0 9 3 1 2 4 1 5 5 0 3 1 0 6 2 0 9 3 1 2 4 1 5 5 m ft 0 3 1 0 6 2 0 9 3 1 2 4 1 5 5 0 3 1 0 6 2 0 9 3 1 2 4 2 1 EXAMPLE ONLY Fall Clearance FC 59 100 kg 130 220 lb 100 140 kg 220 310 lb 2 0 m 6 6...

Page 10: ...1 8 7 2 1 1 0 3 2 0 6 3 0 9 4 1 2 5 1 5 FC A A Anchorage Height W Maximum Work Radius FC Required Fall Clearance Fall Clearance FC 311 420 lb 141 191 kg 9 ft 2 7 m 10 ft 3 0 m 12 ft 3 7 m 14 ft 4 3 m...

Page 11: ...he lifeline to redirect at an angle less than 90 degrees See Figure 6 for reference Do not work on the far side of an opening opposite the anchorage point Use of SRD LEs may require special rescue pro...

Page 12: ...r each leading edge the user will be near SRD 130 220 lb 59 100 kg B 0 ft 0 m 1 ft 0 3 m 2 ft 0 6 m 3 ft 0 9 m 4 ft 1 2 m 5 ft 1 5 m 6 ft 1 8 m A 0 ft 0 0 m 14 2 ft 4 3 m 14 6 ft 4 5 m 15 0 ft 4 6 m 1...

Page 13: ...uld be used See the manufacturer instructions of your full body harness for more information on specific features for interfacing with SRDs A NANO LOK EDGE SRD INTERFACE See Figure 8 for reference The...

Page 14: ...trol 4 4 USING TWIN SRD MODELS Twin SRD models when mounted on a harness may be used for Fall Arrest or Restraint applications Additionally Twin SRDs may be used for climbing applications such as asce...

Page 15: ...ct this product per the procedures listed in the Inspection and Maintenance Log Documentation of each inspection should be maintained by the owner of this equipment An inspection and maintenance log s...

Page 16: ...uctions For a comprehensive list of terms and definitions please visit our website www 3m com FallProtection ifu glossary AUTHORIZED PERSON A person assigned by the employer to perform duties at a loc...

Page 17: ...erie Working Length Longueur de travail ft m R A FC B 0 1 2 3 4 5 6 0 1 2 3 4 14 0 14 5 15 0 15 5 16 0 16 3 16 5 17 0 15 5 16 0 16 5 17 0 17 5 A ft FC ft B ft 17 0 18 0 17 5 17 0 16 5 16 0 18 5 18 0 1...

Page 18: ...evolution or twist along the rope Replace the wire rope assembly if there are any broken wires within 1 inch 25 mm of the ferrules Web Lifelines Figure 12 3 Inspect Webbing and or Rope Lifelines mater...

Page 19: ...19 Figure 12 General Inspection 1 2 3 D C B A Figure 13 Energy Absorber and Connector Inspection A xxxxxxxxxxx C D A E B A 1 2 3 E F D C C...

Page 20: ...o kr Japan 3M Japan Ltd 6 7 29 Kitashinagawa Shinagawa ku Tokyo Phone 81 570 011 321 Fax 81 3 6409 5818 psd jp mmm com WEBSITE 3M com FallProtection FM534873 9 0 0 1 I S O DECLARATION OF CONFORMITY 3M...

Reviews: