1.0  General

Use the 3M

 MS

2™

 Sealant Box 4075-S for moisture resistance and possible reentry applications. This 

procedure can be used in fold-back and inline splices and may be applied either during or after the splicing 

operation. The sealant box is designed for use with the 3M

 MS

2™

 Super Mini Splicing Modules.

Note:  Apply sealant box at ambient temperatures of 32˚F (0˚C) or above.

2.0  Components

 

Insertion tool:   To be used with up to 12 

sealant boxes.

 

Sealant boxes:   Packaged with disposable 

grease retainers and liners.

Insertion Tool

Sealant Box with 
Liner and Retainer

3.0  Sealant Box Installation

3.01  Remove retainer.

3.02  Peel plastic liner away from the sealant. 

Discard liner and retainer.

3.03  Insert module into 3M

 MS

2™

 Sealant Box 

4075-S and press into sealant as far as possible 

with uniform force on each end.