3-1-8. No Function
Projector doesn`t switch
on
Change Interfaceboard
5a/260
Check 390V DC
C2/J3
Check Lamp Door
4/20
Check Mains input
8a/10
Check DC-Voltage
C1/J19
Change Flyback-
Converter
6/10
YES
YES
NO
NO
Change Lamp Ballast
6/70