2
•ReadandfollowUseInstructionsbefore
installation and use of this system.
•Installationmustcomplywithexistingstateor
localplumbingcodes.
•Installoncoldwaterlinesonly.
•Donotinstallonhotwatersupplylines.The
maximumoperatingwatertemperatureofthis
filter system is 100°F (38°C).
•Protectfilterfromfreezing.Drainfilterwhen
roomtemperaturedropsbelow40°F(4.4°C).
•Donotinstallwhereambienttemperatures
maygoabove110°F43°C).
•Donotinstallifwaterpressureexceeds125psi
(862kPa).Ifyourwaterpressureexceeds80
psi,youmustinstallapressurelimitingvalve.
Contactaplumbingprofessionalifyouare
uncertainhowtocheckyourwaterpressure.
•Donotinstallwherewaterhammerconditions
mayoccur.Ifwaterhammerconditionsexist
youmustinstallawaterhammerarrester.
Contactaplumbingprofessionalifyouare
uncertainhowtocheckforthiscondition.
•Ensurethatthelocationandfastenerswillsupportthe
weightofthesystemwheninstalled.
•Thedisposablefilter
must
bereplacedatleast
every12months,attheratedcapacityorsoonerifa
noticeablereductioninflowrateoccurs.
•Donotinstallnearwaterpipeswhichwillbein
pathofadrillingtoolwhenselectingthepositionto
mountthebracket.
•Mountfilterinsuchapositionastopreventitfrombeing
struckbyotheritemsusedintheareaofinstallation.
•Ensurealltubingandfittingsaresecureandfreeofleaks.
•Donotinstallindirectsunlightoroutdoors.
•Whereabackflowpreventiondeviceisinstalledon
awatersystem,adeviceforcontrollingpressure
duetothermalexpansionmustbeinstalled.
•Onplasticfittings,neverusepipesealantor
pipedope.UsePTFEthreadtapeonly,pipe
dope properties may deteriorate plastic.
•Donotuseatorchorotherhightemperaturesourcesnear
filtersystem,filters,plasticfittingsorplasticplumbing.
•SHUTOFFFUELSUPPLYTOWATERHEATER
afterwaterisshutoff.
SAFETY INFORMATION
Read, understand, and follow all safety information contained in these instructions
prior to installation and use of the Filtrete
™
high Performance Whole house large
Capacity systems. Retain these instructions for future reference.
WARNING
WARNING
CAUTION
to reduce the risk associated with ingestion of contaminants:
•Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequate
disinfectionbeforeorafterthesystem.
to reduce the risk associated with a hazardous voltage:
•Ifthehomeelectricalsystemrequirestheuseofthecoldwatersystemasanelectricalsafetyground,ajumperwire
mustbeusedtoensureasufficientgroundconnectionacrossthesysteminstallationpiping–referinstallationto
qualifiedpersonnel.
•Donotinstallnearelectricwiringwhichmaybeinthepathofadrillingtoolwhen
selectingthepositiontomountthefilterbracket.
•Agroundingstrap,bridgingthefilterhead,mustbeinstalledoncopperpipeinstallationstomaintainelectrical
grounding,unlessacopperbypassloopisinstalled.
to reduce the risk of physical injury:
•Depressurizesystemasshowninmanualpriortohousingremoval.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
Indicatesapotentiallyhazardoussituation,which,ifnotavoided,could
resultindeathorseriousinjuryand/orpropertydamage.
Indicatesapotentiallyhazardoussituation,which,ifnotavoided,may
result in property damage.
Intended use:
The Filtrete
™
HighPerformanceWholeHouseLargeCapacitySystemsareintendedforuseinfilteringpotable
waterinhomesandhavenotbeenevaluatedforotheruses.Thesystemistypicallyinstalledatthepointofentryin
autilityormechanicalroomandmustbeinstalledaccordingtotheseinstallationinstructions.
CAUTION
to reduce the risk associated with property damage due to water leakage: